Verify the network configuration

Use this procedure to verify configuration before adding a VLAN to the network.

Steps

  1. Verify that the virtual port channel (vPC) / virtual link tunneling (VLT) is available between the access switches:
    1. For Cisco Nexus switches, type show vpc brief.
    2. For Dell PowerSwitch switches, type show vlt brief.
  2. To verify the port channel between servers, hosts, and access switches are configured, type show port-channel summary.
  3. To verify the port channel between customer network switches and access switches are configured, type show port-channel summary.
  4. To verify that the VLAN is created and enabled on the port channel between the network switches and the access switches, type show vlan.
  5. To verify that SVI is configured on the network switches, type show ip int brief.
  6. To verify that you have the VLAN IP address, mask, and gateway to verify the VLAN configuration, type show vlans.