EMC® VNX® Series Security Configuration Guide for VNX

PDF

Replacing a chassis and SPs from a VNX with encryption enabled

The generated keystore has a relationship to the hardware in the storage system. Removing hardware improperly can cause data to become inaccessible. In situations where the chassis and both SPs need to be replaced, a special procedure is required. Do not replace both SPs simultaneously. Instead, replace one SP and wait until the storage system is back online before replacing the second SP. Alternatively, if the hardware was already replaced and a backup of the keystore is available, you can restore the keystore from the backup with the assistance of EMC Support.