Unisphere and Unisphere Central 2020 R1 Administrator's Guide

Enable Bidirectional CHAP for iSCSI Replication in a Fault Domain

When bidirectional CHAP is enabled for iSCSI replication, the source Storage Center (initiator) challenges the destination Storage Center (target) for a shared secret.

Prerequisites

CHAP must be enabled for the fault domain.

Steps

  1. If you are connected to a Data Collector, select a Storage Center from the drop-down list in the left navigation pane of Unisphere Central.
  2. From the System iconSYSTEM menu, click Ports.
    The Ports view is displayed.
  3. Click the Front End Ports tab.
  4. Expand iSCSI and click the fault domain link.
    The Fault Domain view is displayed.
  5. On the Summary tab, click More Actions icon(More Actions) and select Configure CHAP.
    The Configure CHAP dialog box opens.
  6. Type a shared secret in the Bidirectional CHAP Secret field.