The iSCSI - Fault Domain Configuration page allows you to create fault domains for iSCSI ports.

Steps

  1. Click New button(New) to create an iSCSI fault domain.
    The Create iSCSI Fault Domain dialog box opens.
  2. Type the name of the fault domain in the Name field.
  3. Type the target address for the iSCSI control port in the Target IPv4 Address field.
  4. Type the subnet mask of the iSCSI network in the Subnet Mask field.
  5. Type the IP address of the iSCSI network default gateway in the Gateway IPv4 Address field.
  6. (Optional) Type notes about the fault domain in the Notes field.
  7. Configure the ports to include in the fault domain.
    1. Click Edit icon(Edit).
    2. Select the port to include in the fault domain.
    3. Select the Include in Fault Domain checkbox.
    4. Type the IP address for the port in the IPv4 Address field.
    5. Click Set.
      Repeat the previous steps to add additional ports to the fault domain.
  8. Click OK.
    Repeat the previous steps to create additional fault domains.
  9. Click Next.
  10. View the iSCSI fault domains that have been created, and click Next.