Recovering an OS partition
Follow this procedure to recover your OS partition if becomes corrupt.
Prerequisites
- Failed OS drives have been replaced with new, blank HDDs.
CAUTION: Do not remove or delete the original partitions on the data drives or their associated physical drives.
Steps
- Turn on or restart your system, and press F2 to boot into System Setup.
- Click Device Settings.
- Click Integrated RAID Controller 1: Dell PERC <PERC H730P
Mini> Configuration Utility.
- In the Configuration Utility menu, click Virtual Disk Management.
- Verify the following:
- Your original Data partition or partitions are shown
- No OS partition is listed
- Click Back without making any changes to the data partitions.
- In the Configuration Utility, click Create Virtual Disk.
- In the Create Virtual Disk dialog box, select the RAID Level and Capacity options.
- Select RAID Level — See the standard RAID configurations above.
- Select Physical Disks From — Unconfigured Capacity.
- Click Select Physical Disks, choose the drives to configure for RAID.
- Click Apply Changes.
- Wait for the Success screen to display The operation has been performed successfully, and then click OK.
- Under Create Virtual Disk Parameters set the following options and leave remaining options set to their default settings:
- Virtual Disk Name — enter a unique name such as OS
- Virtual Disk Size — in GB (currently this partition is 140GB).
- Default Initialization — Fast (for example)
- Click Create Virtual Disk.
- In the Warning screen, select Confirm and click Yes.
- When the message appears that the virtual disk was created successfully, click OK.
- Click Back two times to return to the Configuration Utility Main Menu.
- Click Virtual Disk
Management.
- Verify that both the newly-created OS partition and the existing data
partitions are present.
- Click Back to return to the Configuration Utility Main Menu.
- Click Controller Management.
- For Select Boot Device select OS
Partition.
- Click Back to return to the Configuration Utility Main Menu and click Finish.
- Click Finish again and
reboot the system.
- During the restart, press F2 to boot into System Setup .
- On the System Setup Main Menu, click System BIOS.
- In the System BIOS options, select .
- Verify that the Integrated RAID Controller 1: PERC H730P Mini
is present and is selected as the Boot Option.
- Back-out of the BIOS, saving any changes as needed.
- Restart the system and press F10=Lifecycle Controller to proceed to deploying the OS.