You can update the firmware and software of shared resources from the
Resources page.
This capability is available on the
PowerFlex appliance and
PowerFlex rack offerings only.
A firmware or software update on a node that is part of a cluster is successful only if the node is set to maintenance mode.
PowerFlex Manager sets nodes in a cluster to maintenance mode before performing an update. To ensure that the node remains in maintenance mode, ensure that there are other nodes available in the cluster to host the virtual machines of the node being updated.
A firmware update on a VMware cluster is successful only if the cluster is properly configured for HA. For example, the host system can be set in maintenance mode and the virtual machines can be moved from one host to another in the cluster.
CAUTION:Check the
Alerts page before performing the upgrade. Look for major and critical alerts before proceeding.
About this task
If any resources are not compliant with the default compliance catalog, you can update the firmware or software to the minimum recommended level.
Steps
On the menu bar, click
Resources.
Select the check box for one or more resources and click
Update Resources.
On the
Update Details page, confirm that all the information is correct. For a
PowerFlex gateway, you must reconfigure one or more nodes before proceeding with the upgrade.
Click
Next.
On the
Summary page, select one of the following options:
Allow PowerFlex Manager to perform firmware and software updates now—Select this option to update the firmware and software immediately.
PowerFlex Manager applies the firmware updates and reboots the selected resources immediately. If the resource is in use, this update could be disruptive.
Schedule firmware and software updates—Select this option and then select the date and time to update the firmware and software.
PowerFlex Manager applies the firmware updates at the selected date and time and reboots the selected resources. If the resource is in use, this update could be disruptive.
If you are updating a
PowerFlex gateway, type
UPDATE POWERFLEX to confirm that you are ready to proceed with the update.
Click
Finish.