192.168.163.17 is the NVMe over TCP controller IP address (data 1 VLAN) and
192.168.163.251 is the NVMe over TCP host IP address (data 1 VLAN).
Discovery Log Number of Records 4, Generation counter 2
=====Discovery Log Entry 0======
trtype: tcp
adrfam: ipv4
subtype: nvme subsystem
treq: not specified, sq flow control disable supported
portid: 1
trsvcid: 4420
subnqn: nqn.1988-11.com.dell:powerflex:00:c5ea88815e07e40f
traddr: 192.168.163.19
eflags: not specified
sectype: none
=====Discovery Log Entry 1======
trtype: tcp
adrfam: ipv4
subtype: nvme subsystem
treq: not specified, sq flow control disable supported
portid: 17
trsvcid: 4420
subnqn: nqn.1988-11.com.dell:powerflex:00:c5ea88815e07e40f
traddr: 192.168.163.18
eflags: not specified
sectype: none
=====Discovery Log Entry 2======
trtype: tcp
adrfam: ipv4
subtype: nvme subsystem
treq: not specified, sq flow control disable supported
portid: 32
trsvcid: 4420
subnqn: nqn.1988-11.com.dell:powerflex:00:c5ea88815e07e40f
traddr: 192.168.161.20
eflags: not specified
sectype: none
=====Discovery Log Entry 3======
trtype: tcp
adrfam: ipv4
subtype: nvme subsystem
treq: not specified, sq flow control disable supported
portid: 49
trsvcid: 4420
subnqn: nqn.1988-11.com.dell:powerflex:00:c5ea88815e07e40f
traddr: 192.168.163.17
eflags: not specified
sectype: non
On the NVMe over TCP client, connect the client to the
PowerFlex NVMe over TCP target system.
Configure the
/etc/nvme/discovery.conf file
to add the parameters used in the NVMe discover command and use
-p at the end of the command for persistent controller discovery.
Persistent discovery controller will:
Notify a host of fabric changes after initial discovery.
Host retains connection to discovery controller.
NOTE:Add an entry for all the SDT IP addresses discovered in the previous step: