Manual SDC configuration/verification

If there are problems connecting to a PowerFlex system after a reboot, users can modify the drv_cfg.txt file or use the drv_cfg utility to ensure that the SDC reconnects to the MDM automatically upon node restart/reboot.

To do this, perform one of the following procedures:

  • Edit /etc/emc/scaleio/drv_cfg.txt and change the #MDM line to include each IP address for any node(s) containing an MDM in your cluster.

    For example, change the line:

    From:

    #mdm 10.20.30.40

    To:

    mdm 10.108.158.48,10.108.158.49

    where .48 is the primary node, and .49 is the secondary node. The tiebreaker node should not be included.

  • Use the drv_cfg binary or drv_cfg.exe on Windows to re-attach the MDM.
  • Rescan all volumes using the drv_cfg utility.