Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Upgrade Dell PowerFlex to v3.6.x

PDF

Disable IPMI on a R630/R730xd server

Use the following procedure to disable IPMI on PowerFlex R630/R730xd nodes.

About this task

You can run this procedure at any time post-deployment.

Prerequisites

Ensure that:

  • You have network connectivity to the server.
  • You know the IP address of the iDRAC port.
  • You know the password for accessing iDRAC as root). If necessary, the customer can give you the credentials.

Steps

  1. Open a new browser session and log in to iDRAC.
  2. On the left menu, click iDRAC settings > Network.
  3. On the Network page upper menu, click IPMI Settings.
    The page jumps to the IPMI settings area.
  4. In the Value column, clear the Enable IPMI Over LAN check box, and then click Apply.
    The Network page refreshes.
  5. On the upper menu, click IPMI Settings again, and then confirm that the Enable IPMI Over LAN check box is cleared .
  6. Log out of iDRAC.
  7. Repeat the above steps on every R630/R730xd node in the system.