Disable IPMI on a R630/R730xd server
Use the following procedure to disable IPMI on
PowerFlex R630/R730xd nodes.
About this task
You can run this procedure at any time post-deployment.
Prerequisites
Ensure that:
- You have network connectivity to the server.
- You know the IP address of the iDRAC port.
- You know the password for accessing iDRAC as root). If necessary, the customer can give you the credentials.
Steps
-
Open a new browser session and log in to iDRAC.
-
On the left menu, click
.
-
On the
Network page upper menu, click
IPMI Settings.
The page jumps to the
IPMI settings area.
-
In the
Value column, clear the
Enable IPMI Over LAN check box, and then click
Apply.
The
Network page refreshes.
-
On the upper menu, click
IPMI Settings again, and then confirm that the
Enable IPMI Over LAN check box is cleared .
-
Log out of iDRAC.
-
Repeat the above steps on every R630/R730xd node in the system.