Must contain one or more of the following parameters:
mdmAddresses – List of MDM IP addresses that the
PowerFlex Gateway will use to connect to the MDM (for performance improvement, place the primary MDM IP addresses before the secondary ones)
mdmPort – MDM port
gatewayAdminPassword – Password for installation manager, get/update
PowerFlex Gateway configuration, and add primary MDM
systemId – ID of the system configured by
mdmAddresses. If
systemId is left empty, it will be populated on the first invocation of
/api/login. At every
/api/login, the system ID value is compared to the ID of the
PowerFlex cluster (MDM). If the IDs are different (
mdmAddresses points to a cluster that does not match the
systemId), an error message is displayed, and all login tokens (/api/login,
/api/gatewayLogin) are invalidated. None of the
PowerFlex Gateway clients will be able to send requests to the MDM until one of the following happens:
systemId is configured to the correct value
mdmAddresses is configured to the correct IP addresses
systemId is set to an empty value. In this case, on the first invocation of
/api/login, the value for
systemId will be populated according to the ID of the matching
mdmAddresses.
If the value for
systemId is different from the configured
systemId (and the configured
systemId is not empty), all login tokens (/api/login,
/api/gatewayLogin) are invalidated.
snmpSamplingFrequency – MDM sampling frequency in seconds. If sampling frequency is set to
0, the SNMP trap sender will be disabled, and no sampling to the MDM will be performed.
snmpResendFrequency – Resend frequency of SNMP traps, in minutes. If resend frequency is set to
0, all traps will be sent in every sampling.
snmpTrapsReceiverIp – SNMP trap receivers' IP addresses (supports up to two comma-separated or semi-colon-separated IP addresses)