CAUTION:Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized
in your product documentation, or as directed by the online or telephone
service and support team. Damage due to servicing that is not authorized
by Dell is not covered by your warranty. Read and follow the safety
instructions that came with the product.
Steps
If the system is operational, run the appropriate diagnostic
test. See Using system diagnostics for available diagnostic tests.
If diagnostics indicate a fault, follow the corrective actions
provided by the diagnostic program.
If the system is not operational, turn off the system and
attached peripherals, and unplug the system from the power source.
Wait at least 10 seconds and then reconnect the system to the power
source.
Turn on the system and attached peripherals and note the
messages on the screen.
If an error message is displayed indicating a fault with
a specific memory module, go to step 12.
Enter the System Setup and check the system memory setting.
Make any changes to the memory settings, if needed.
If the memory settings match the installed memory but the
problem still persists, go to step 12.
Turn off the system and attached peripherals, and disconnect
the system from the electrical outlet.
Remove the system cover.
Check the memory channels and ensure that they are populated
correctly.
NOTE:See the
system event log or system messages for the location of the failed
memory module. Reinstall the memory device.
Reset the memory modules in their sockets.
Install the system.
Enter the System Setup and check the system memory setting.
If the problem is not resolved, proceed with the next step.
Remove the system cover.
If a diagnostic test or error message indicates a specific
memory module as faulty, swap or replace the module with a known good
memory module.
To troubleshoot an unspecified faulty memory module, replace
the memory module in the first DIMM socket with a module of the same
type and capacity.
If an error message is displayed on the screen, this may indicate
a problem with the installed DIMM type(s), incorrect DIMM installation,
or defective DIMM(s). Follow the on-screen instructions to resolve
the problem.
Install the system cover.
As the system boots, observe any error message that is
displayed and the diagnostic indicators on the front of the system.
If the memory problem persists, repeat step 12 through
step 15 for each memory module installed.