This basetype is used by show expander-status for controller A and controller B.

Table 1. sas-status-controller-a properties
Name Type Description
enclosure-id uint32 Enclosure ID.
drawer-id uint8 For a 2U12 or 2U24 enclosure:
  • 255 : N/A
For a 5U84 enclosure:
  • 0: Top
  • 1: Bottom
baseplane-id uint8 Baseplane ID.
expander-id uint8 Expander ID.
controller string
  • A : Controller A.
  • B : Controller B.
controller-numeric uint32 Numeric equivalents for controller values.
  • 0: B
  • 1: A
wide-port-index uint32 The wide-port index.
phy-index uint32 The PHY index.
wide-port-role string The wide-port role.
  • Unknown
  • Drive
  • Drawer Egress
  • Drawer Ingress
  • Expansion Egress
  • Expansion Ingress
  • SC Primary
  • SC Alternate
  • Inter Expander
  • Unused
wide-port-role-numeric uint32 Numeric equivalents for wide-port-role values.
  • 0: Unknown
  • 1: Drive
  • 2: Drawer Egress
  • 3: Drawer Ingress
  • 4: Expansion Egress
  • 5: Expansion Ingress
  • 6: SC Primary
  • 7: SC Alternate
  • 8: Inter Expander
  • 9: Unused
wide-port-num uint32 The wide-port number.
type string The PHY type.
  • Drive: Drive slot PHY.
  • SC-P: Storage Controller primary PHY.
  • SC-A: Storage Controller alternate PHY.
  • Expander-Universal-0: Expansion port 0 universal PHY.
  • Expander-Universal-1: Expansion port 1 universal PHY.
  • Expander-Universal-2: Expansion port 2 universal PHY.
  • Drawer0-Ingress-0: Drawer 0 ingress PHY 0.
  • Drawer0-Ingress-1: Drawer 0 ingress PHY 1.
  • Drawer0-Ingress-2: Drawer 0 ingress PHY 2.
  • Drawer0-Egress-0: Drawer 0 egress PHY 0.
  • Drawer0-Egress-1: Drawer 0 egress PHY 1.
  • Drawer0-Egress-2: Drawer 0 egress PHY 2.
  • Drawer1-Ingress-0 Drawer 1 ingress PHY 0.
  • Drawer1-Ingress-1: Drawer 1 ingress PHY 1.
  • Drawer1-Ingress-2: Drawer 1 ingress PHY 2.
  • Drawer1-Egress-0: Drawer 1 egress PHY 0.
  • Drawer1-Egress-1: Drawer 1 egress PHY 1.
  • Drawer1-Egress-2: Drawer 1 egress PHY 2.
status string PHY status.
  • Unavailable : No status information is available.
  • Enabled - Healthy : The PHY is enabled and healthy
  • Enabled - Degraded : The PHY is enabled but degraded.
  • Disabled : The PHY has been disabled by a user or by the system.
status-numeric uint32 Numeric equivalents for status values.
  • 0: Unavailable
  • 1: Enabled - Healthy
  • 2: Enabled - Degraded
  • 3: Disabled
elem-status string The SES status that corresponds to the PHY status.
  • Disabled : Critical condition is detected.
  • Error : Unrecoverable condition is detected. Appears only if there is a firmware problem related to PHY definition data.
  • Non-critical : Non-critical condition is detected.
  • Not Used : Element is not installed in enclosure.
  • Unknown : Either:
    • Sensor has failed or element status is not available. Appears only if an I/O module indicates it has fewer PHYs than the reporting I/O module, in which case all additional PHYs are reported as unknown.
    • Element is installed with no known errors, but the element has not been turned on or set into operation.
elem-status-numeric uint32 Numeric equivalents for elem-status values.
  • 0: Error
  • 1: OK
  • 2: Disabled
  • 3: Non-critical
  • 4: Error
  • 5: Not Used
  • 6: Unknown
  • 7: Unknown
elem-disabled string
  • Enabled : PHY is enabled.
  • Disabled : PHY is disabled.
elem-disabled-numeric uint32 Numeric equivalents for elem-disabled values.
  • 0: Enabled
  • 1: Disabled
elem-reason string More information about the status value.
  • Blank if elem-status is OK.
  • Error count interrupts : PHY disabled because of error-count interrupts.
  • PHY control : PHY disabled by a SES control page as a result of action by a Storage Controller or user.
  • Not ready : PHY is enabled but not ready. Appears for SC-1 PHYs when the partner I/O module is not installed. Appears for Drive, SC-1, or Ingress PHYs when a connection problem exists such as a broken connector.
  • Firmware reboot: PHY disabled because of a firmware reboot.
  • Disk removed : PHY disabled because drive slot is empty.
  • Unused - disabled by default : PHY is disabled by default because it is not used.
  • Excessive PHY changes : PHY is disabled because of excessive PHY change counts.
  • Did not initialize : PHY is enabled but not ready because it did not pass COMINIT.
elem-reason-numeric uint32 Numeric equivalents for elem-reason values.
  • 0 : (blank)
  • 3: Error count interrupts
  • 5: PHY control
  • 6: Not ready
  • 7: Firmware reboot
  • 8: Disk removed
  • 9: Unused - disabled by default
  • 10: Excessive PHY changes
  • 11: Did not initialize
change-counter hex32 Number of times the PHY originated a BROADCAST (CHANGE). A BROADCAST (CHANGE) is sent if doubleword synchronization is lost or at the end of a Link Reset sequence.
code-violations hex32 Number of times the PHY received an unrecognized or unexpected signal.
disparity-errors hex32 Number of doublewords containing running disparity errors that have been received by the PHY, not including those received during Link Reset sequences. A running disparity error occurs when positive and negative values in a signal do not alternate.
crc-errors hex32 In a sequence of SAS transfers (frames), the data is protected by a cyclic redundancy check (CRC) value. The crc-errors value specifies the number of times the computed CRC does not match the CRC stored in the frame, which indicates that the frame might have been corrupted in transit.
conn-crc-errors hex32 Number of times the lane between two expanders experienced a communication error.
lost-dwords hex32 Number of times the PHY has lost doubleword synchronization and restarted the Link Reset sequence.
invalid-dwords hex32 Number of invalid doublewords that have been received by the PHY, not including those received during Link Reset sequences.
reset-error-counter hex32 Number of times the expander performed a reset of error counters.
flag-bits hex32 PHY status flag bits, for internal use.