Dell PowerVault ME5 Series Storage System CLI Reference Guide

PDF

power-supplies

This basetype is used by show power-supplies.

Table 1. power-supplies properties
Name Type Description
durable-id string Power supply ID in the format psu_enclosure-ID.power-supply-number.
url string For internal use only.
enclosure-url string For internal use only.
enclosure-id uint32 Enclosure ID.
dom-id uint32 For internal use only.
serial-number string Power supply serial number.
part-number string FRU part number.
description string FRU long description.
name string Power supply identifier and location.
fw-revision string
  • (blank): Not applicable.
  • Firmware revision of the power supply.
revision string FRU hardware revision level.
model string Power supply model.
vendor string Power supply vendor.
location string Power supply location, as viewed from the back of the enclosure.
position string Power supply position, as viewed from the back of the enclosure.
  • Left
  • Right
  • Top
  • Bottom
position-numeric uint32 Numeric equivalents for position values.
  • 0: Left
  • 1: Right
  • 2: Top
  • 3: Bottom
dash-level string FRU template revision number.
fru-shortname string FRU short description.
mfg-date string Date and time, in the format year-month-day hour:minutes:seconds (UTC), when the power supply module was manufactured.
mfg-date-numeric uint32 Unformatted mfg-date value.
mfg-location string City, state/province, and country where the FRU was manufactured.
mfg-vendor-id string JEDEC ID of the FRU manufacturer.
configuration-serialnumber string Configuration serial number.
dc12v uint32 Deprecated.
dc5v
dc33v
dc12i
dc5i
dctemp
health string
  • OK
  • Degraded
  • Fault
  • N/A
  • Unknown
health-numeric uint32 Numeric equivalents for health values.
  • 0: OK
  • 1: Degraded
  • 2: Fault
  • 3: Unknown
  • 4: N/A
health-reason string If Health is not OK, the reason for the health state.
health-recommendation string If Health is not OK, the recommended actions to take to resolve the health issue.
status string Power supply status.
  • Up
  • Warning
  • Error
  • Not Present
  • Unknown
status-numeric uint32 Numeric equivalents for statusvalues.
  • 0: Up
  • 1: Warning
  • 2: Error
  • 3: Not Present
  • 4: Unknown
conditions Embedded; see health-conditions.
unhealthy-component Embedded; see unhealthy-component.
fan-details Embedded; see fan .