Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerVault ME5 Series Storage System CLI Reference Guide

PDF

alerts

This basetype is used by show alerts.

Table 1. alerts properties
Name Type Description
id uint32 Alert sequence number.
component string Component name.
serial-number string Component serial number.
description string Component description.
durable-id string Unique alert ID.
condition-id string Unique condition ID.
severity string Alert severity.
  • CRITICAL: A failure occurred that may cause a controller to shut down. Correct the problem immediately.
  • ERROR: A failure occurred that may affect data integrity or system stability. Correct the problem as soon as possible.
  • WARNING: A problem occurred that may affect system stability but not data integrity. Evaluate the problem and correct it if necessary.
  • INFORMATIONAL: A configuration or state change occurred, or a problem occurred that the system corrected. No action is required.
severity-numeric uint32 Numeric equivalent for the preceding value.
  • 0: INFORMATIONAL
  • 1: WARNING
  • 2: ERROR
  • 3: CRITICAL
resolved string
  • No: The alert condition is not resolved.
  • Yes: The alert condition is resolved.
resolved-numeric uint32 Numeric equivalent for the preceding value.
  • 0: No
  • 1: Yes
acknowledged string
  • Yes: The alert has been acknowledged.
  • No: The alert has not been acknowledged.
acknowledged-numeric uint32 Numeric equivalent for the preceding value.
  • 0: No
  • 1: Yes
acknowledged-by string Username that acknowledged the alert.
acknowledged-time string Date and time when the alert was acknowledged.
acknowledged-time-numeric uint32 Unformatted version of the preceding value.
detected-time string The most recent date and time when the alert condition was detected.
detected-time-numeric uint32 Unformatted version of the preceding value.
resolved-time string Date and time when the alert condition was resolved. N/A if unresolved.
resolved-time-numeric uint32 Unformatted version of the preceding value. 0 if unresolved.
reminder-time string Not supported.
reminder-time-numeric uint32 Not supported.
hit-count uint32 Number of times an alert has occurred without being acknowledged.
basetype string Basetype of the component.
health string
  • OK
  • Fault
  • N/A
health-numeric uint32 Numeric equivalent for the preceding value.
  • 0: OK
  • 2: Fault
  • 4: N/A
reason string A message describing the alert condition.
reason-numeric uint32 Numeric equivalent for the preceding value.
reason-id uint32 Not used.
recommended-action string The recommended action to take to resolve the alert condition.
recommended-action-numeric uint32 Numeric equivalent for the preceding value.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\