background-scrub
|
string
|
Shows whether disks in disk groups are automatically checked for disk defects to ensure system health. The interval between a scrub finishing and starting again is specified by the
background-scrub-interval parameter.
-
Disabled: Background disk-group scrub is disabled.
-
Enabled: Background disk-group scrub is enabled.
|
background-scrub-numeric
|
uint32
|
Numeric equivalents for
background-scrub values.
|
background-scrub-interval
|
uint16
|
Shows the interval between background disk-group scrub finishing and starting again, from 0 to 2160 hours (90 days).
|
partner-firmware-upgrade
|
string
|
Shows whether component firmware versions are monitored and will be automatically updated on the partner controller.
-
Disabled: Partner firmware upgrade is disabled.
-
Enabled: Partner firmware upgrade is enabled.
|
partner-firmware-upgrade-numeric
|
uint32
|
Numeric equivalents for partner-firmware-upgrade values.
|
utility-priority
|
string
|
Priority at which data-redundancy utilities, such as disk group verify and reconstruct, run with respect to I/O operations competing for the system's processors. (This does not affect disk group background scrub, which always runs at “background” priority.)
-
High: Utilities have higher priority than host I/O. This can cause heavy I/O to be slower than normal.
-
Medium: Utility performance is balanced with host I/O performance.
-
Low: Utilities run at a slower rate with minimal effect on host I/O.
|
utility-priority-numeric
|
uint32
|
Numeric equivalents for
utility-priority values.
|
smart
|
string
|
Shows whether SMART (Self-Monitoring Analysis and Reporting Technology) is enabled or disabled for disks.
-
Detect-Only: Each disk in the system retains its individual SMART setting, as will new disks added to the system.
-
Enabled: SMART is enabled for all disks in the system and will be enabled for new disks added to the system.
-
Disabled: SMART is disabled for all disks in the system and will be disabled for new disks added to the system.
|
smart-numeric
|
uint32
|
Numeric equivalents for
smart values.
-
0: Detect-Only
-
1: Enabled
-
2: Disabled
|
dynamic-spares
|
string
|
Shows whether the storage system will automatically use a compatible disk as a spare to replace a failed disk in a disk group if no compatible spare is available. The dynamic spares feature does not apply to ADAPT disk groups.
-
Disabled: The dynamic spares feature is disabled.
-
Enabled: The dynamic spares feature is enabled.
|
emp-poll-rate
|
string
|
Shows the interval in seconds at which the storage system will poll each enclosure's Enclosure Management Processor (EMP) for status changes, from 5 to 3600 seconds.
|
host-cache-control
|
string
|
Shows whether hosts are allowed to use the SCSI
MODE SELECT command to change the storage system's write-back cache setting.
-
Disabled: Hosts can use the SCSIMODE SELECT command to change the write-back cache setting. This is the default.
-
Enabled: Hosts cannot override the storage system's write-back cache setting.
|
host-cache-control-numeric
|
uint32
|
Numeric equivalents for
host-cache-control values.
|
sync-cache-mode
|
string
|
Shows how the SCSI
SYNCHRONIZE CACHE command is handled.
-
Immediate: Good status is returned immediately and cache content is unchanged.
-
Flush to Disk: Good status is returned only after all write-back data for the specified volume is flushed to disk.
|
sync-cache-mode-numeric
|
uint32
|
Numeric equivalents for
sync-cache-mode values.
-
0: Immediate
-
1: Flush to Disk
|
missing-lun-response
|
string
|
Shows whether host drivers may probe for LUNs until the host drivers reach the LUN to which they have access.
-
Not Ready: Sends a reply that there is a LUN where a gap has been created but that it’s “not ready.” Sense data returned is sensekey = 2, code = 4, qualifier = 3.
-
Illegal Request: Sends a reply that there is a LUN but that the request is “illegal.” Sense data returned is sensekey = 5, code = 25h, qualifier = 0.
|
missing-lun-response-numeric
|
uint32
|
Numeric equivalents for
missing-lun-response values.
-
0: Not Ready
-
1: Illegal Request
|
controller-failure
|
string
|
Shows whether the cache policy will change from write-back to write-through when a controller fails.
-
Disabled: The controller failure trigger is disabled.
-
Enabled: The controller failure trigger is enabled (default).
|
controller-failure-numeric
|
uint32
|
Numeric equivalents for
controller-failure values.
|
super-cap-failure
|
string
|
Shows whether the cache policy will change from write-back to write-through when the supercapacitor that provides backup power for cache is not fully charged or fails.
-
Disabled: The supercapacitor failure trigger is disabled.
-
Enabled: The supercapacitor failure trigger is enabled.
|
super-cap-failure-numeric
|
uint32
|
Numeric equivalents for
super-cap-failure values.
|
memory-card-failure
|
string
|
Shows whether the cache policy will change from write-back to write-through when memory card is not detected during POST (Power-On Self-Test), fails during POST, or fails during controller operation.
-
Disabled: The memory-card failure trigger is disabled.
-
Enabled: The memory-card failure trigger is enabled.
|
memory-card-failure-numeric
|
uint32
|
Numeric equivalents for the memory-card-failure values.
|
power-supply-failure
|
string
|
Shows whether the cache policy will change from write-back to write-through when a power supply fails.
-
Disabled: The power-supply failure trigger is disabled.
-
Enabled: The power-supply failure trigger is enabled.
|
power-supply-failure-numeric
|
uint32
|
Numeric equivalents for power-supply-failure values.
|
fan-failure
|
string
|
Shows whether the cache policy will change from write-back to write-through when a fan fails.
-
Disabled: The fan failure trigger is disabled.
-
Enabled: The fan failure trigger is enabled.
|
fan-failure-numeric
|
uint32
|
Numeric equivalents for
fan-failure values.
|
temperature-exceeded
|
string
|
Shows whether the system will shut down a controller when its temperature exceeds the critical operating range.
-
Disabled: The over-temperature trigger is disabled.
-
Enabled: The over-temperature trigger is enabled.
|
temperature-exceeded-numeric
|
uint32
|
Numeric equivalents for
temperature-exceeded values.
|
partner-notify
|
string
|
Shows whether the partner controller will be notified when a trigger condition occurs.
-
Disabled: Notification is disabled. The partner controller will continue using its current caching mode.
-
Enabled: Notification is enabled. The partner controller will change to write-through mode for better data protection.
|
partner-notify-numeric
|
uint32
|
Numeric equivalents for
partner-notify values.
|
auto-write-back
|
string
|
Shows whether the cache policy will change from write-through to write-back when the trigger condition is cleared.
-
Disabled: Auto-write-back is disabled.
-
Enabled: Auto-write-back is enabled.
|
auto-write-back-numeric
|
uint32
|
Numeric equivalents for
auto-write-back values.
|
disk-dsd-enable
|
string
|
Shows whether spinning disks that are available or are global spares will spin down after a period of inactivity shown by the
disk-dsd-delay property.
-
Disabled: Drive spin down for available disks and global spares is disabled.
-
Enabled: Drive spin down for available disks and global spares is enabled.
|
disk-dsd-enable-numeric
|
uint32
|
Numeric equivalents for
disk-dsd-enable values.
|
disk-dsd-delay
|
uint16
|
Specifies the period of inactivity in minutes after which spinning disks that are available or are global spares will spin down, from 1 to 360 minutes. The value 0 means spin down is disabled.
|
background-disk-scrub
|
string
|
Shows whether disks that are not in disk groups are automatically checked for disk defects to ensure system health. The interval between background disk scrub finishing and starting again is 72 hours.
-
Disabled: Background disk scrub is disabled.
-
Enabled: Background disk scrub is enabled.
|
background-disk-scrub-numeric
|
uint32
|
Numeric equivalents for
background-disk-scrub values.
|
managed-logs
|
string
|
Shows whether the managed logs feature is enabled, which allows log files to be transferred from the storage system to a log-collection system to avoid losing diagnostic data as logs fill.
-
Disabled: The managed logs feature is disabled.
-
Enabled: The managed logs feature is enabled.
|
managed-logs-numeric
|
uint32
|
Numeric equivalents for
managed-logs values.
|
single-controller
|
string
|
For a system that had two controller modules but now has only one and is intended to be used as a single-controller system, this property shows whether the operating/redundancy mode is set to Single Controller. This prevents the system from reporting the absent partner controller as an error condition. This parameter does not affect any other system settings. Installing a second, functional controller module will change the mode to Active-Active ULP.
-
Enabled: Single Controller mode is enabled.
-
Disabled: Single Controller mode is disabled.
|
single-controller-numeric
|
string
|
Numeric equivalents for
single-controller values.
|
auto-stall-recovery
|
string
|
Shows whether the auto stall recovery feature is enabled, which detects situations where a controller stall is preventing I/O operations from completing, and recovers the system so that at least one controller is operational, thus avoiding data-unavailability situations. This feature focuses failover/recovery stalls. When a stall is detected, event 531 is logged.
-
Disabled: Auto stall recovery is disabled.
-
Enabled: Auto stall recovery is enabled.
|
auto-stall-recovery-numeric
|
uint32
|
Numeric equivalents for
auto-stall-recovery values.
|
delete-override
|
string
|
Not supported.
|
delete-override-numeric
|
uint32
|
Not supported.
|
restart-on-capi-fail
|
string
|
Shows whether a Storage Controller that experiences a CAPI hang will be forced to restart. A CAPI hang is perceived as a management-interface hang. As part of the restart process, a dump file is created and event 107 is logged. To provide the dump file to technical support for debugging, use the Save Logs action in the
PowerVault Manager.
|
restart-on-capi-fail-numeric
|
uint32
|
Numeric equivalents for
restart-on-capi-fail values.
|
large-pools
|
string
|
Deprecated.
|
large-pools-numeric
|
uint32
|
Deprecated.
|
ssd-concurrent-access
|
string
|
Not supported.
|
ssd-concurrent-access-numeric
|
uint32
|
Not supported.
|
slot-affinity
|
string
|
Not supported.
|
slot-affinity-numeric
|
uint32
|
Not supported.
|
random-io-performance-optimization
|
string
|
Shows whether random I/O performance optimization is enabled or disabled.
|
random-io-performance-optimization-numeric
|
uint32
|
Numeric equivalents for
random-io-performance-optimization values.
|
cache-flush-timeout
|
string
|
Shows whether the cache flush timeout is enabled or disabled.
|
cache-flush-timeout-numeric
|
uint32
|
Numeric equivalents for
cache-flush-timeout values.
|
remanufacture
|
string
|
Not supported.
|
remanufacture-numeric
|
uint32
|
Not supported.
|
hedged-reads-timeout
|
string
|
Shows whether the
hedged-reads-timeout is enabled or disabled.
-
Disabled: The
hedged-reads-timeout is disabled.
-
Enabled: The hedged-reads-timeout is enabled.
|
hedged-reads-timeout-numeric
|
uint32
|
Numeric equivalents for
hedged-reads-timeout values.
|
auto-map
|
string
|
Shows whether the
auto map feature is enabled or disabled.
|
auto-map-numeric
|
uint32
|
Numeric equivalents for
auto-map values.
|
auto-unmap
|
string
|
Shows whether the
auto unmap feature is enabled or disabled.
|
auto-unmap-numeric
|
uint32
|
Numeric equivalents for
auto-unmap values.
|