When installing a system with expansion enclosures attached, the enclosure IDs might not agree with the physical cabling order. This issue occurs if the controller was previously attached to enclosures in a different configuration, and the controller attempts to preserve the previous enclosure IDs.
About this task
To correct this condition, ensure that both controllers are up, and perform a rescan using the
PowerVault Manager or the CLI. The rescan reorders the enclosures, but it can take up to two minutes to correct the enclosure IDs.
NOTE Reordering expansion enclosure IDs only applies to dual-controller mode. If only one controller is available, due to a controller failure, a manual rescan does not reorder the expansion enclosure IDs.
Steps
To perform a rescan using the
PowerVault Manager:
Verify that both controllers are operating normally.
Select
Maintenance > Hardware.
Select
Actions > Rescan All Disks
Click
Rescan.
To perform a rescan using the CLI, type the following command:
rescan