Dell PowerVault ME5 Series Storage System Deployment Guide

Configure RHEL 7 iSCSI initiators to connect to the storage system

Steps

  1. From the server terminal or console, run the following iscsiadm command to discover targets (port A0):
    iscsiadm –m discovery –t sendtargets –p <IP>

    Where <IP> is the IP address. For example:

    iscsiadm –m discovery –t sendtargets –p 192.68.10.200

  2. With the discovery output, log in to each portal by running the iscsiadm command:
    1. Run iscsiadm –m node –T <full IQN > -p <IP>
      Where <full IQN> is the full IQN listing from the output in step 1 and <IP> is the IP address.
    2. Repeat the login for each controller host port using the discovery command output in step 1.
    3. Reboot the host to ensure that all targets are automatically connected.