put
firmware-file flash
CAUTION:Do not perform a power cycle or controller restart during a firmware update. If the update is interrupted or there is a power failure, the module might become inoperative. If this issue occurs, contact technical support. The module might need to be returned to the factory for reprogramming.
NOTE:If you attempt to load an incompatible firmware version, the message
*** Code Load Fail. Bad format image. *** is displayed and after a few seconds the FTP/SFTP prompt is redisplayed. The code is not loaded.
Firmware update typically takes 10 minutes for a controller having current CPLD firmware, or 20 minutes for a controller with downlevel CPLD firmware. If the controller enclosure has attached enclosures, allow additional time for each enclosure management processor (EMP) to be updated in the expansion module. It typically takes 2.5 minutes for each EMP in a drive enclosure.
NOTE:If you are using a Windows FTP/SFTP client, during firmware update a client-side FTP/SFTP application issue or timeout setting can cause the FTP/SFTP session to be aborted. If this issue persists, try using the
PowerVault Manager to perform the update, use another client, or use another FTP/SFTP application.
If the Storage Controller cannot be updated, the update operation is canceled. If the FTP/SFTP prompt does not return, quit the FTP/SFTP session and log in again. Verify that you specified the correct firmware file and repeat the update. If this problem persists, contact technical support.
When firmware update on the local controller is complete, the FTP session returns to the
sftp> prompt, and the FTP/SFTP session to the local MC is closed. Use a management interface to monitor the system and determine when the update is complete.
If the Partner Firmware Update (PFU) feature is enabled, allow an extra 5 minutes to 20 minutes for both controllers to be updated.