The following steps provide an example of configuring an additional NVMe/TCP storage network on two Dell PowerSwitch Series S4148 Top-of-Rack (ToR) switches.
You can cable the
PowerStore T model appliance nodes to the switches before or after you perform these steps. For steps, see
Cable the nodes to the ToR switches.
Configure the Storage network to run over port 6 on ToR Switch1.
interface ethernet 1/1/6
description NodeA_IO_0_port_1
no shutdown
switchport mode trunk
switchport trunk allowed vlan 210
mtu 9216
no shutdown
Repeat steps 1 - 4 on the second ToR switch (Switch2) as demonstrated below.
NOTE:Be sure to use the correct Ethernet ports when configuring the second ToR switch (Switch2).
Table 1. Code sample for configuring ToR switches for a new iSCSI Storage networkCode sample for configuring the Switch1 and Switch 2 with a new iSCSI network.
Tor Switch1
ToR Switch2
configure terminal
interface vlan 210
description NVMe_Network2
exit
interface ethernet 1/1/6
description NodeA_IO_0_port_1
no shutdown
switchport mode trunk
switchport trunk allowed vlan 210
mtu 9216
no shutdown
configure terminal
interface vlan 210
description NVMe_Network2
exit
interface ethernet 1/1/49
description NodeB_IO_0_port_1
no shutdown
switchport mode trunk
switchport trunk allowed vlan 210
mtu 9216
no shutdown