Verify the operation of a replacement DIMM

Steps

  1. From PowerStore Manager, select Hardware.
  2. Select the appliance where you replaced the DIMM.
  3. On the Components card, under Internal View, expand ExpansionEnclosure.
  4. Select the relevant DIMM.
    The status of the replacement DIMM should read Healthy. If the status is still Faulted, wait a few minutes and refresh PowerStore Manager. If the status does not change, ensure that the DIMM is correctly seated, or contact your service provider.
  5. You can also verify the operation of a replacement DIMM by using the following commands:
    To display the DIMM information:
     svc_diag list --expansion_hardware --sub_option dimm
    To display the status of the NVMe expansion enclosure:
    svc_diag list --expansion_hardware --sub_option status
    To display the verbose output of all of the hardware in the NVMe expansion enclosure including health and status.
    svc_diag list --expansion_hardware
    NOTE:The svc_diag list command takes a few minutes to run.