Port-channel with LACP for full network automation or partial network automation

All nodes are connected to access and leaf pair switches.

NOTE:If a multi-VLAN number is used from the below table, you must add the corresponding multi-VLAN number for each row.
Node vSwitch Port-channel/Interface mode Speed (GB) Mode Required VLANs Node LB
PowerFlex management controller 1.0 FE_DvSwitch 91,92,93,94 10/25 Active 104,105,130,150 LAG-Active-Src and dest IP and TCP/UDP
PowerFlex management controller 1.0 BE_DvSwitch 81,82,83,84 10/25 Active 103,106,113,151-154 (153 and 154 optional) LAG-Active-Src and dest IP and TCP/UDP
PowerFlex management controller 2.0 FE_DvSwitch 91,92,93,94 10/25 Active 104,105,130,140,150 LAG-Active-Src and dest IP and TCP/UDP
PowerFlex management controller 2.0 BE_DvSwitch 81,82,83,84 10/25 Active 103,141,142,143,151-154 (153 and 154 optional) LAG-Active-Src and dest IP and TCP/UDP
PowerFlex management controller 1.0 or PowerFlex management controller 2.0 oob_DvSwitch Access 1/10 NA 101 NA
PowerFlex compute-only node (VMware ESXi) Cust_DvSwitch 2,4,6 10/25/100 Active 104-106 LAG-Active-Src and dest IP and TCP/UDP
PowerFlex compute-only node (VMware ESXi) Flex-DvSwitch 1,3,5 10/25/100 Active 151-154 (153 and 154 optional) LAG-Active-Src and dest IP and TCP/UDP
PowerFlex compute-only node (Linux) Bond0 2,4,6 10/25/100 Active 104 - 105 LAG-Active-Src and dest IP and TCP/UDP
PowerFlex compute-only node (Linux) Bond1 1,3,5 10/25/100 Active 151 - 154 (153, 154 optional) Mode 4
PowerFlex hyperconverged node Cust_DvSwitch 2,4,6 10/25/100 Active 104-106,150 LAG-Active-Src and dest IP and TCP/UDP
PowerFlex hyperconverged node Flex-DvSwitch 1,3,5 10/25/100 Active 151-154 (153 and 154 optional) LAG-Active-Src and dest IP and TCP/UDP
PowerFlex storage-only node Bond0 2,4,6 10/25/100 Active 150,151,153,161 (153 optional) Mode 4
PowerFlex storage-only node Bond1 1,3,5 10/25/100 Active 152,154,162 (154 optional) Mode 4
Aggregation 1900 100 Active All VLANs as specified VLAN mapping section