  • NOTE: For additional information about environmental measurements for specific system configurations, see Dell.com/environmental_datasheets.
Table 1. Temperature specifications .

The table below shows the optimal working temperature specifications:

Temperature Specifications
Storage –40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
Maximum temperature gradient (operating and storage) 20°C/h (68°F/h)
Table 2. Relative humidity specifications .

The table below shows the relative humidity specification during operations and storage:

Relative humidity Specifications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be non-condensing at all times.
Operating 10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.
Table 3. Maximum vibration specifications .

The table below shows the maximum vibration specifications during operations and storage:

Maximum vibration Specifications
Operating 0.26 G rms at 5 Hz to 350 Hz (all three axes).
Storage 1.88 G rms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Table 4. Maximum shock specifications .

The table below shows the maximum shock specifications during operations and storage:

Maximum shock Specifications
Operating Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.
Table 5. Maximum altitude specifications .

The table below shows the maximum altitude specifications during operations and storage.

Maximum altitude Specifications
Operating

3048 m ( 10,000 ft)

Storage 12,000 m (39,370 ft)
Table 6. Operating temperature de-rating specifications .

The table below shows the operating temperature de-rating specifications:

Operating temperature de-rating Specifications
Up to 35°C (95°F) Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).
35°C to 40°C (95°F to 104°F) Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).
40°C to 45°C (104°F to 113°F) Maximum temperature is reduced by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft).