Installing the EDSFF E3.S PERC module

Prerequisites

  1. Follow the safety guidelines listed in the Safety instructions.
  2. Follow the procedure listed in Before working inside your system.
  3. Remove the cooling fan cage assembly.
  4. Remove the drive backplane cover.
  5. If required, remove the air shroudor remove the GPU air shroud.
  6. Route the cable properly to prevent the cable from being pinched or crimped.
    NOTE:See cable routing section; configuration 46 for more information.

Steps

  1. Align and install PERC card to the guides on the front PERC tray.
  2. Align and Install the PERC shroud on the PERC card.
  3. Using a Phillips #2 screwdriver, tighten the four screws to secure the PERC shroud to the PERC tray.
    Figure 1. Installing the PERC card into PERC tray
    NOTE:Route the battery cable to the clips on the front PERC shroud.
    This image shows Installing the front PERC card
  4. Insert the battery tab into the battery holder and ensure the battery that it is firmly seated.
    Figure 2. Installing the battery into the battery holder
    This image shows Installing the battery into the battery holder
  5. Align and connect the PERC power cable to the PERC card.
  6. NOTE:Route the PERC cable into the PERC tray cable holder.
    Tilt the battery holder assembly to align the tabs with the PERC tray.
  7. Press the battery holder assembly on to the PERC tray.
  8. Connect the battery power cable to the front PERC card.
    NOTE:Route the battery cable into the front PERC shroud cable holder.
    Figure 3. Installing the battery holder assembly into the PERC shroud
    This image shows Installing the battery holder assembly into the PERC shroud
    NOTE:Procedure to install the other PERC card is similar.
  9. Align the guide slots on the PERC tray with the guide pins on the system.
    NOTE:Connect all the cables to the PERC card before lowering the tray. See cable routing section for more information.
  10. Lower the PERC tray, until it is firmly seated and secured.
    NOTE:The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
    Figure 4. Installing the PERC tray
    This image shows Installing the EDSFF E3.S PERC module.

Next steps

  1. Connect all the cables, observe the cable routing.
    NOTE:See cable routing section; configuration 46 for more information.
  2. Install the cooling fan cage assembly.
  3. If removed, install the air shroudor install the GPU air shroud.
  4. Install the drive backplane cover.
  5. Follow the procedure listed in After working inside your system.