Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell PowerEdge R760 Installation and Service Manual

EDSFF E3.S drive led codes

The LEDs on the drive carrier indicate the state of each drive. The LEDs on the EDSFF E3.S drive have two LEDs: an activity LED (green) and a locate/fault LED (blue/amber). The activity LED blinks whenever the drive is accessed.

EDSFF E3.S drive led codes

Figure 1. EDSFF E3.S drive indicators

This image shows EDSFF E3.S drive indicators

  1. Drive activity LED indicator
  2. Drive status LED indicator
  3. Drive capacity label
E3.S hard drives have Green LED and Blue/Amber LED.
  • Green LED shows : Drive power status , Activity
  • Blue/Amber LED shows: Drive Fault, Locate

EDSFF indicator behavior

Table 1. EDSFF indicator behaviorThis table shows EDSFF indicator behavior.
Pattern Name Description Blue Element Amber Element
Locate This device is being identified. ON (1 sec ON 1 sec OFF) OFF
Fault The device is in a fault condition. OFF ON (2 sec ON 1 sec OFF)
N/A This device does not have fault or locate device. OFF OFF
NOTE:Locate behavior overrides Fault state.

Green LED

The green LED is driven and controlled by the device. The two functions for this LED are defined as follows:

  • Power: This function indicates that the device has power and has no issues with its power regulation. Once the green LED is ON, it shall either remain ON or blink at the activity frequency unless the device determines power is no longer within its operating range.
  • Activity: This function indicates if the device is being used.
Table 2. LED and device state per function for Green LEDLED and device state per function for Green LED
Function/Device state LED state
Power ON/Device is powered, no activity occurring. ON
Activity/Device is powered, host initiated I/O activity occurring. 4 Hz nominal blink rate
Power OFF/Device is not powered. OFF