Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products

Dell EMC PowerEdge R740xd2 Installation and Service Manual

Removing a memory module

Prerequisites

  1. Follow the safety guidelines listed in Safety instructions.
  2. Power off the system and all attached peripherals.
  3. Disconnect the system from the electrical outlet, and disconnect the peripherals.
  4. Open the drive bays, remove all drives, and then close the drive bays.
  5. Remove the power supply units.
  6. Remove the system from the rack and place it on an ESD work bench. For more information, see the Rail Installation Guide available at https://www.dell.com/poweredgemanuals.
  7. Remove the system cover.
  8. Remove the air shroud.
Locate the appropriate memory module socket.
WARNING: Allow the memory modules to cool after you power off the system. Handle the memory modules by the card edges and avoid touching the components or metallic contacts on the memory module.

Steps

  1. Push the ejectors outward on both ends of the memory module socket to release the memory module from the socket.
  2. Lift and remove the memory module from the system.
    CAUTION: Handle memory modules only by the card edges, ensuring not to touch the middle of the memory module or metallic contacts.
    NOTE:If you are removing the memory module permanently, install a memory module blank. The procedure to install a memory module blank is similar to that of the memory module.
    Figure 1. Removing a memory module
    This image shows how to remove a memory module.