Warning |
The system board ambient temperature is less than
the lower warning threshold.
|
Server temperature is getting cool. |
Critical |
The system board ambient temperature is less than
the lower critical threshold.
|
Server temperature is getting cold. |
Warning |
The system board ambient temperature is greater
than the upper warning threshold.
|
Server temperature is getting warm. |
Critical |
The system board ambient temperature is greater
than the upper critical threshold.
|
Server temperature is getting too hot. |
Critical |
The system board Current Latch current is outside
of the allowable range
|
Current crossed a failing threshold. |
Critical |
The system board battery failed. |
CMOS battery is not present or has no voltage. |
Warning |
The storage battery is low. |
ROMB battery is low. |
Critical |
The storage battery failed. |
CMOS battery is not present or has no voltage. |
Critical |
The CPU <number> <voltage sensor name >
voltage is outside of the allowable range.
|
|
Critical |
The system board<voltage sensor name > voltage
is outside of the allowable range.
|
|
Critical |
The mezzanine card <number> <voltage sensor
name > voltage is outside of the allowable range.
|
|
Critical |
The storage <voltage sensor name > voltage
is outside of the allowable range.
|
|
Critical |
CPU <number> has an internal error (IERR). |
CPU failure. |
Critical |
CPU <number> has a thermal trip (over-temperature)
event.
|
CPU overheated. |
Critica |
CPU <number> configuration is unsupported. |
Incorrect processor type or in wrong location. |
Critical |
CPU <number> is absent. |
Required CPU is missing or not present. |
Critical |
Mezz B<slot number> Status: Add-in Card sensor
for Mezz B<slot number>, install error was asserted.
|
Incorrect Mezzanine card installed for IO fabric. |
Critical |
Mezz C<slot number> Status: Add-in Card sensor
for Mezz C<slot number>, install error was asserted.
|
Incorrect Mezzanine card installed for IO fabric. |
Critical |
Drive <number> is removed. |
Storage Drive was removed. |
Critical |
Fault detected on Drive <number>. |
Storage Drive failed. |
Critical |
The system board fail-safe voltage is outside of
the allowable range.
|
This event is generated when the system board voltages
are not at normal levels.
|
Critical |
The watchdog timer expired. |
The iDRAC watchdog timer expires and no action
is set.
|
Critical |
The watchdog timer reset the system. |
The iDRAC watchdog detected that the system has
crashed (timer expired because no response was received from Host)
and the action is set to reboot.
|
Critical |
The watchdog timer powered off the system. |
The iDRAC watchdog detected that the system has
crashed (timer expired because no response was received from Host)
and the action is set to power off.
|
Critical |
The watchdog timer power cycled the system. |
The iDRAC watchdog detected that the system has
crashed (timer expired because no response was received from Host)
and the action is set to power cycle.
|
Critical |
Log is full. |
The SEL device detects that only one entry can
be added to the SEL before it is full.
|
Warning |
Persistent correctable memory errors detected on
a memory device at location <location>.
|
|
Warning |
Persistent correctable memory error rate has increased
for a memory device at location <location>.
|
Correctable ECC errors reach a critical rate. |
Critical |
Multi-bit memory errors detected on a memory device
at location <location>.
|
An uncorrectable ECC error was detected. |
Critical |
An I/O channel check NMI was detected on a component
at bus <number> device <number> function <number>.
|
A critical interrupt is generated in the I/O Channel. |
Critical |
An I/O channel check NMI wa detected on a component
at slot <number>.
|
A critical interrupt is generated in the I/O Channel. |
Critical |
A PCI parity error was detected on a component
at bus <number> device <number> function <number>.
|
Parity error was detected on the PCI bus. |
Critical |
A PCI parity error was detected on a component
at slot <number>.
|
Parity error was detected on the PCI bus. |
Critical |
A PCI system error was detected on a component
at bus <number> device <number> function <number>.
|
PCI error detected by device. |
Critical |
A PCI system error was detected on a component
at slot <number>.
|
PCI error detected by device. |
Critical |
Persistent correctable memory error logging disabled
for a memory device at location <location>.
|
Single bit error logging is disable when too many
SBE get logged for a memory device.
|
Critical |
All event logging is disabled. |
|
Non- Recoverable |
CPU protocol error detected. |
The processor protocol entered a non-recoverable
state.
|
Non- Recoverable |
CPU bus parity error detected. |
The processor bus PERR entered a non-recoverable
state.
|
Non- Recoverable |
CPU initialization error detected. |
The processor initialization entered a non-recoverable
state.
|
Non- Recoverable |
CPU machine check detected. |
The processor machine check entered a non-recoverable
state.
|
Critical |
Memory redundancy is lost. |
|
Critical |
A bus fatal error was detected on a component at
bus <number> device <number> function <number>.
|
Fatal error is detected on the PCIe bus. |
Critical |
A software NMI was detected on a component at
bus <number> device <number> function <number>.
|
Chip error is detected. |
Critical |
Failed to program virtual MAC address on a component
at bus <number> device <number> function <number>.
|
Flex address could be programmed for this device. |
Critical |
Device option ROM on mezzanine card <number>
failed to support Link Tuning or FlexAddress.
|
Option ROM does not support Flex address or linking
tuning.
|
Critical |
Failed to get Link Tuning or FlexAddress data
from iDRAC.
|
|