Checking the chassis type sticky bits for the PowerEdge C6320p sled

Steps

Use the IPMI cmd: ipmitool –U server_user_name –P server_user_pass_word –H server IP –I lanplus raw 0x30 0xc8 0x01 0x0A 0x05 0x00 0x00 0x00 to check if the chassis type is set for the PowerEdge C6320p sled. For example: To check if the chassis type is set for the PowerEdge C6320p sled execute this command
ipmitool –U root –P calvin –H 10.3.25.127 –I lanplus raw  0x30 0xc8 0x01 0x0A 0x05 0x00 0x00 0x00
Response: 0x0a 0x05 0x00 0x00 0x00 0x5 0x00 0x70 0x8e 0x02