Review the following issues related to storage units in
PowerProtect Data Manager Appliance.
Creating storage unit fails when maximum MTree and Users count on
protection storage system reached
When you add a protection policy or create a storage unit in
PowerProtect Data Manager Appliance, storage unit creation fails if you reach the maximum MTree and Users count on the selected
protection storage system.
PowerProtect Data Manager Appliance enables you to finish adding a protection policy without a storage unit. However, if you subsequently run a backup with this protection policy, the backup process is suspended indefinitely with no error message.
To continue backup operations, you must perform a cleanup on the
protection storage system.
Discrepancy between storage unit capacity reported in
PowerProtect Data Manager Appliance and
protection storage Virtual Edition
Due to differences in space calculation (physical capacity versus logical capacity), there is a discrepancy between storage unit capacity reported in
PowerProtect Data Manager Appliance and
protection storage Virtual Edition. To see the storage unit capacity displayed in the
PowerProtect Data Manager Appliance UI, select
Infrastructure > Storage, select the storage system in the
Protection Storage tab, and select
More Actions > Manage Storage Units. For example, the
protection storage unit capacity displayed in the
PowerProtect Data Manager Appliance UI might be greater than the capacity displayed in DDVE.
To determine the storage unit capacity, use DDVE instead.
Data is not available for the Topic