After importing the foreign configuration of the associated global hot-spare drive on a PERC12 series controller, the drive is still reported as both Online and global hot-spare

Error Message:
After importing the foreign configuration of the associated global hot-spare drive on a PERC12 or HBA465 series controller, the drive is still reported as both Online and global hot-spare
Probable Cause:
The drive type of a commissioned Global Hot Spare was incorrectly set as Global Hot Spare during the foreign import operation.
Corrective Action:
Reset the controller by running the perccli2 /c0 reset command at the PERC12 CLI.