Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell EMC PowerEdge XR2 Technical Specifications

Environmental specifications

NOTE For additional information about environmental certifications, please refer to the Product Environmental Datasheet located with the Manuals & Documents on www.dell.com/poweredgemanuals
Table 1. Temperature specificationsThe table preceding shows the optimal working temperature specifications.
Temperature Specifications
Storage –40°C–70°C (–40°F–158°F) per Mil-Std 810G Method 501.6, Proc 1
Continuous operation (for altitude less than 950 m or 3117 ft) 5°C–45°C (41°F–104°F), with no direct sunlight on the equipment
Fresh air For information about fresh air, see Expanded Operating Temperature section.
Excursion temperature 55°C per Mil-Std 810G Method 501.6 Proc II
NOTE Configuration restrictions will apply. For more information, contact DellEMC sales support representative.
Maximum temperature gradient (operating and storage) 20°C/h (68°F/h)
Table 2. Relative humidity specificationsThe table preceding shows the relative humidity specification during operations and storage.
Relative humidity Specifications
Storage 5% to 95% RH with 33°C (91°F) maximum dew point Atmosphere must be noncondensing at all times.
Operating 5% to 85% relative humidity with 29°C (842°F) maximum dew point
Table 3. Maximum vibration specificationsThe table preceding shows the maximum vibration specifications during operations and storage.
Maximum vibration Specifications
Operating Random vibration per Mil-Std 810G method 514.7, 0.00220783 g2/Hz at 10 Hz to 500 Hz (overall 1.04 rms), all 3 axes, 1 hour per axis
Storage Mil-Std 810G Procedure I, Cat 4, Fig 514.7 C-1 (US highway truck vibration), 1 hour per axes
Table 4. Maximum shock specificationsThe table preceding shows the maximum shock specifications during operations and storage.
Maximum shock Specifications
Operating Mil-Std 810G method 516.7, Proc I, 40G, 11 ms, 3 shocks in +/- directions in 3 axes (total 18 shocks)
Storage Mil-Std 810G method 516.7, Proc I, 40G, 11 ms, 3 shocks in +/- directions in 3 axes (total 18 shocks)
Table 5. Maximum altitude specificationsThe table preceding shows the maximum altitude specifications during operations and storage.
Maximum altitude Specifications
Operating Mil-Std 810G method 500.6, Proc. II, air carriage, 15,000 ft for 1 hour after stabilization
Storage Mil-Std 810G method 500.6, Proc. I, 40,000 ft for 1 hour after stabilization

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\