Action performed was: <Action>
|
Specifies the automatic server recovery action
that was performed, for example:
Action performed
was: Power cycle
|
Action requested was: <Action>
|
Specifies the user initiated host control action
that was requested, for example:
Action requested
was: Reboot, shutdown OS first
|
Additional details: <Additional details
for the events>
|
Specifies possible additional details about the
specified device, for example:
Additional details:
Memory device: DIMM_1A Serial number: 11111111
Memory device: DIMM_1B Serial number:
22222222
|
<Additional power supply status information>
|
Specifies any additional power supply information
pertaining to the event, for example:
Power
supply input AC is off, Power supply POK (power OK) signal is not
normal, Power supply is turned off
|
Battery sensor status: <status>
|
Specifies the status reported by the battery sensor,
for example:
Battery sensor status: Predictive
failure
|
Chassis intrusion state: <Intrusion
state>
|
Specifies the chassis intrusion state (open or
closed), for example:
Chassis intrusion state:
Open
|
Chassis location: <Name of chassis>
|
Specifies the name of the chassis that generated
the message, for example:
Chassis location:
Main System Chassis
|
Configuration error type: <type of
configuration error>
|
Specifies the type of configuration error that
occurred, for example:
Configuration error
type: Revision mismatch
|
Current sensor value (in Amps): <Reading>
|
Specifies the current sensor value in amps, for
example:
Current sensor value: 7.853
|
Date and time of action: <Date and time>
|
Specifies the date and time that an automatic
server recovery action was performed, for example:
Date and time of action: Fri May 30 23:55:44 2003.
|
Description: <Description of event>
|
Specifies the description of the event that occurred,
for example:
Description: Chipset Err: Critical
Event sensor, front panel NMI / diagnostic interrupt was asserted.
|
Device location: <Location in chassis>
|
Specifies the location of the device in the specified
chassis, for example:
Device location: Mem
Card A
|
Discrete current state: <State>
|
Specifies the state of the current sensor, for
example:
Discrete current state: Good
|
Discrete temperature state: <State>
|
Specifies the state of the temperature sensor,
for example:
Discrete temperature state: Good
|
Discrete voltage state: <State>
|
Specifies the state of the voltage sensor, for
example:
Discrete voltage state: Good
|
Fan sensor value: <Reading>
|
Specifies the fan speed in revolutions per minute
(RPMs) or On/Off, for example:
Fan sensor value
(in RPM): 2600
Fan sensor value:
Off
|
Log type: <Log type>
|
Specifies the type of hardware log, for example:
Log type: Embedded Server Management (ESM)
|
Memory device bank location: <Bank
name in chassis>
|
Specifies the name of the memory bank in the system
that generated the message, for example:
Memory
device bank location: Bank_1
|
Memory device location: <Device name
in chassis>
|
Specifies the location of the memory module in
the chassis, for example:
Memory device location:
DIMM_A
|
Number of devices required for full redundancy:
<Number>
|
Specifies the number of power supply or cooling
devices required to achieve full redundancy, for example:
Number of devices required for full redundancy: 4
|
Peak value (in Watts): <Reading>
|
Specifies the peak value in Watts, for example:
Peak value (in Watts): 125
|
Possible memory module event cause: <list
of causes>
|
Specifies a list of possible causes for the memory
module event, for example:
Possible memory
module event cause: Single bit warning error rate exceeded
Single bit error logging disabled
|
Power Supply type: <type of power supply>
|
Specifies the type of power supply, for example:
Power Supply type: VRM
|
Pre-failure state was: <State>
|
Specifies the status of the previous memory message,
for example:
Pre-failure state was: Failed
|
Previous redundancy state was: <State>
|
Specifies the status of the previous redundancy
message, for example:
Previous redundancy state
was: Lost
|
Previous state was: <State>
|
Specifies the previous state of the sensor, for
example:
Previous state was: OK (Normal)
|
Processor sensor status: <status>
|
Specifies the status of the processor sensor, for
example:
Processor sensor status: Configuration
error
|
Redundancy unit: <Redundancy location
in chassis>
|
Specifies the location of the redundant power supply
or cooling unit in the chassis, for example:
Redundancy unit: Fan Enclosure
|
SD card device type: <Type of SD card
device>
|
Specifies the type of SD card device, for example:
SD card device type: Hypervisor
|
SD card state: <State of SD card>
|
Specifies the state of the SD card, for example:
SD card state: Present, Failed
|
Sensor location: <Location in chassis>
|
Specifies the location of the sensor in the specified
chassis, for example:
Sensor location: CPU1
|
Temperature sensor value (in degrees Celsius):
<Reading>
|
Specifies the temperature in degrees Celsius, for
example:
Temperature sensor value (in degrees
Celsius): 30
|
Voltage sensor value (in Volts): <Reading>
|
Specifies the voltage sensor value in volts, for
example:
Voltage sensor value: 1.693
|