Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

PowerScale OneFS 9.3.0.0 CLI Administration Guide

Create a dedicated Access Zone on a CAVA server

A dedicated Access Zone is automatically created when the CAVA service is enabled in the PowerScalecluster.

The AvVendor access zone is restricted. You cannot create SMB shares and NFS exports in the AvVendor access zone.

NOTE: The AvVendor access zone is not deleted when CAVA is disabled, so access zone settings are preserved.
  1. Run the following command to enable the CAVA service:
    isi antivirus cava settings modify --service-enabled=1
  2. View the CAVA settings and confirm Server Enable is set to Yes:
    isi antivirus cava settings modify --service-enabled=1

    isi antivirus cava settings view
           Service Enabled: Yes
         Scan Access Zones: System
                   IP Pool: groupnet0.subnet0.pool1
             Report Expiry: 8 weeks, 4 days
              Scan Timeout: 1 minute
    Cloudpool Scan Timeout: 1 minute
         Maximum Scan Size: 0.00kB
  3. Verify the AvVendor creation in the Access Zone list:
    isi zone zones list

    Output similar to the following is displayed

    Name     Path
    --------------
    System   /ifs
    AvVendor /ifs
    --------------
    Total: 2
    