Description | SCP import operation that is performed using a template file created using an older version of iDRAC may complete with errors about unsupported attributes. |
Workaround | Use the SCP template from the latest installed version of iDRAC, and then try the import operation. |
Systems Affected | All system supported by this release. |
Tracking number | 262132 |
Description | Power supply unit displayed as Absent in the Hardware Inventory page after iDRAC firmware is upgraded to version 7.00.00.00. |
Workaround | Perform an iDRAC reboot or run the racadm getsensorinfo command to see the information. |
Systems Affected | All systems supported by this release. |
Tracking number | 267183 |
Description | The PCIe Type attribute in PCIe System Slot section denotes the slot capability. Therefore, PCIe Type attribute that is reported for PCIe devices in PCIe System Slot reports the slot capable PCIe type and not the generation of the PCIe device present in the slot. |
Workaround | N/A |
Systems Affected | All system supported by this release. |
Tracking number | 263510 |
Description | On scheduling two update jobs for a GPU and NICs together, the GPU update may fail while the NIC update is successful. |
Workaround | Avoid clubbing the GPU firmware updates with any other firmware update. |
Systems Affected | All systems supported by this release. |
Tracking number | 258437 |
Description | Lifecycle Controller GUI Firmware Inventory page may display the GPU Firmware installation time incorrectly. |
Workaround | N/A |
Systems Affected | All system configurations with Intel GPU cards, that are supported by this release. |
Tracking number | 258238 |
Description | Job gets timed out with a message in Lifecycle (LC) logs "JCP052: The Job was in running state and made no progress for the allocated time". |
Workaround | Change the JobTimeout attribute value in iDRAC from 120 to 180 minutes. |
Systems Affected | All 16th generation of PowerEdge servers with four-unit configurations supported by this release. |
Tracking number | 259415 |
Description | PSU firmware update may fail, and PSU state changes to disabled. |
Workaround | Uninstall and reinstall the PSU. |
Systems Affected | All systems with 700 W PSU supported by this release. |
Tracking number | 258611 |
Description | Some keys or key combination may not provide the correct output for languages other than English. |
Workaround | Use the physical keyboard or Windows On-Screen Keyboard. |
Systems Affected | All systems supported by this release. |
Tracking number | 181505 |