Description | Unable to create a backplane firmware update job after running the "racadm systemerase reinstallfw" command immediately after performing "racadm systemerase lcdata". |
Workaround | Restart the iDRAC and then try "racadm systemerase reinstallfw" command. |
Systems Affected | All systems supported by this release. |
Tracking number | 265093 |
Description | A device configuration job to enable or disable security on BOSS devices may fail with JCP042 message. A PR19 configuration update success message is also logged as the configuration of attributes succeeds. |
Workaround | Retry the configuration job. |
Systems Affected | All systems supported by this release. |
Tracking number | 263709 |
Description | iDRAC fails to display the drives in the enclosure PowerVault MD 2412, PowerVault MD 2424, or PowerVault MD 2460 after a warm boot. |
Workaround | Perform an iDRAC reset. |
Systems Affected | All systems supported by this release configured with PowerVault MD 2412, PowerVault MD 2424, or PowerVault MD 2460 enclosures. |
Tracking number | 261523 |
Description | Changing external enclosure element (EMM/PSU/Fan/TempProbes) inventory/monitoring and Enclosure AssetTag and AssetName may fail for PowerVault MD 2412, PowerVault MD 2424, or PowerVault MD 2460 that is connected to the server through PERC H840. |
Workaround | N/A |
Systems Affected | All systems that supported by this release with PERC H840 connected to SAS4 JBODs on PowerVault MD 2412 or PowerVault MD 2424, or PowerVault MD 2460. |
Tracking number | 260963, 260401, 257318 |
Description | In servers that are attached to PowerVault MD2460 connected through PERC HBA355e, iDRAC may not display the enclosure components such as Fan, Temperature Probes, EMM, and PSU. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 256962 |
Description | Physical disks that are connected to a BOSS-N1 controller are not unlocking on system boot. |
Workaround | Perform a system cold boot. |
Systems Affected | All systems supported by this release. |
Tracking number | 261135 |
Description | GET method on Drives URI not displaying the FIPS140ComplianceDescriptor property for hard drives in the response. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 261024 |
Description | Hot reinsertion of enclosure cables to PERC H840 may cause a change in the enclosure state as Removed and summary of the drive slots in the enclosure page may be displayed as Slot empty. |
Workaround | Reset the iDRAC. |
Systems Affected | All 14th and 15th generation of PowerEdge Servers with PERC H840 external controller connected to JBODs. |
Tracking number | 260816 |
Description | The value for Redundant Path for an enclosure is displaying as Not Present in iDRAC interfaces. |
Workaround | Perform an iDRAC reset or power cycle the system. |
Systems Affected | All systems supported by this release. |
Tracking number | 260767 |
Description | PR36 Lifecycle (LC) Log may not be displayed for a few E3 drives. For example, if all the drive slots are populated with E3 devices, the update completes for all the drives, however, only a few drives report the PR36 message in LC logs. |
Workaround | See the iDRAC inventory page if the version is updated for the drive. |
Systems Affected | All systems supported by this release. |
Tracking number | 256017 |
Description | After performing a SystemErase or LCWipe, PERC 12 controllers such as H965i, H965i Front adapters may not be displayed under the iDRAC Storage page. |
Workaround | Reboot the host system or perform a Racreset. |
Systems Affected | All 16th Generation of PowerEdge servers supported by this release with PERC12 controllers. |
Tracking number | 257716 |
Description | After HBA355e controller firmware update, iDRAC interfaces may display duplicate entries for enclosure and drives under the storage enclosure and storage physical disk page. |
Workaround | Perform an iDRAC reset. |
Systems Affected | All systems supported by this release. |
Tracking number | 251527 |
Description | RAC0128 error is displayed after vFlash initializes with a failure in image upload that is caused by a network disruption during Create Partition task. |
Workaround | Reset the iDRAC. |
Systems Affected | All systems supported by this release. |
Tracking number | 252865 |
Description | If iDRAC and PERC have the same Key Ids then PERC Rekey command fails. |
Workaround | Use the iDRAC Rekey command instead of PERC Rekey. |
Systems Affected | All systems supported by this release. |
Tracking number | 230629/189445 |
Description | After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message. |
Workaround | Restart the host system. |
Systems Affected | All systems supported by this release. |
Tracking number | 197049 |