Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

iDRAC9 Version 6.10.00.00 Release Notes

PDF

Storage and storage controllers

Table 1. iDRAC GUI not displaying front backplane image iDRAC GUI may fail to display the front backplane image of the supported backplane with 3.5" drives and 2.5" drives in all the slots.
Description iDRAC GUI may fail to display the front backplane image of the supported backplane with 3.5" drives and 2.5" drives in all the slots.
Workaround Ensure that at least one Physical disk form factor matches with backplane form factor.
Systems Affected All systems with front backplanes supported by this release.
Tracking number 244410
Table 2. iDRAC inventory displaying secured drive as Encryption capable Drives that are encrypted by a third-party application may be displayed a "Encryption Capable" instead of "Secured by Foreign Key"
Description Drives that are encrypted by a third-party application may be displayed a "Encryption Capable" instead of "Secured by Foreign Key"
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 247168
Table 3. Drive speed for SAS4 drives not available iDRAC may not display the drive speed for SAS4 drives.
Description iDRAC may not display the drive speed for SAS4 drives.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 230060
Table 4. PERC Rekey failingIf iDRAC and PERC have the same Key Ids then PERC Rekey command fails.
Description If iDRAC and PERC have the same Key Ids then PERC Rekey command fails.
Workaround Use the iDRAC Rekey command instead of PERC Rekey.
Systems Affected All systems supported by this release.
Tracking number 230629/189445
Table 5. Max Capable Speed reported as Unknown Maximum capable speed for SAS4 drives that are configured with PERC9, PERC10, or PERC 11 is reported as Unknown in iDRAC.
Description Maximum capable speed for SAS4 drives that are configured with PERC9, PERC10, or PERC 11 is reported as Unknown in iDRAC.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 230290
Table 6. LC logs display incorrect version change for disks After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message.
Description After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message.
Workaround Restart the host system.
Systems Affected All systems supported by this release.
Tracking number 197049
Table 7. Deleting VD creates pending operation with empty data When existing VD is deleted from iDRAC GUI using delete VD operation from the Virtual disk option and then added to pending operation, the pending operation displays no information. However, the delete VD pending operation is created successfully.
Description When existing VD is deleted from iDRAC GUI using delete VD operation from the Virtual disk option and then added to pending operation, the pending operation displays no information. However, the delete VD pending operation is created successfully.
Workaround To successfully delete the VD and add to pending operations, perform the following steps:
  1. Select the Configuration option in iDRAC GUI
  2. Select Storage Configuration, then select the Controller and click Apply now.
Systems Affected All systems supported by this release.
Tracking number 184393

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\