iDRAC9 Version 6.10.80.00 Release Notes

PDF

iDRAC firmware

Table 1. SystemConfigHash attribute hash value changingSystemConfigHash attribute hash value gets modified for SCP preview operation even though no configuration change is applied.
Description SystemConfigHash attribute hash value gets modified for SCP preview operation even though no configuration change is applied.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 261912/260667
Table 2. SCP import failingSCP import fails with an error on the attribute VNCServer.1#Password, if the template used is in Clone or Replace mode.
Description SCP import fails with an error on the attribute VNCServer.1#Password, if the template used is in Clone or Replace mode.
Workaround Remove the attribute VNCServer.1#Password from the SCP file and try again.
Systems Affected All systems supported by this release.
Tracking number 242618/227881
Table 3. Boot Once enabled for UEFIAfter setting the first boot device to UEFI device path, the Boot Once option remains enabled for selection.
Description After setting the first boot device to UEFI device path, the Boot Once option remains enabled for selection.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 261955