iDRAC9 Version 6.10.30.00 Release Notes

PDF

Monitoring and alerting

Table 1. Metrics missing in reports The following Telemetry reports may intermittently miss a few metrics: PowerMetrics, PSUMetrics, ThermalMetrics, StorageSensor, MemeorySensor, AggregationMetrics, SystemUsage, FPGASensor, PowerStataistics, PowerStatistics, CPUMemMetrics.
Description The following Telemetry reports may intermittently miss a few metrics: PowerMetrics, PSUMetrics, ThermalMetrics, StorageSensor, MemeorySensor, AggregationMetrics, SystemUsage, FPGASensor, PowerStataistics, PowerStatistics, CPUMemMetrics.
Workaround Perform any of the following:
  • Disable and enable one or more Metric Report Definitions corresponding to the report.
  • Reset iDRAC.
Systems Affected All systems supported by this release.
Tracking number 259718
Table 2. SWC5011 event in Lifecycle logs SWC5011 error is logged in Lifecycle logs while performing a CPLD update.
Description SWC5011 error is logged in Lifecycle logs while performing a CPLD update.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 253595/250881
Table 3. System Fan information refreshing intermittentlyIn iDRAC Cooling page, information about Fans refreshing continuously and status for fans 7 to 9 is displayed as unknown.
Description In iDRAC Cooling page, information about Fans refreshing continuously and status for fans 7 to 9 is displayed as unknown.
Workaround Fan information may take a few seconds to display. Ignore the fan status for fans 7 to 9.
Systems Affected PowerEdge R7525 with liquid cooling configuration.
Tracking number 252955
Table 4. System inlet temperature lower than warning thresholdWarning displayed in Lifecycle logs or SEL stating The system inlet temperature is less than the lower warning threshold." while running cold boot cycle with iDRAC.
Description A warning is displayed in Lifecycle logs or SEL stating that The system inlet temperature is less than the lower warning threshold, while running cold boot cycle with iDRAC.
Workaround Perform an iDRAC reset.
Systems Affected PowerEdge XE8545
Tracking number 247091
Table 5. SEL events may not be correctly displayed in the earlier versions of iDRACNew SEL events were introduced in iDRAC versions 4.4x. If iDRAC is rolled back to an earlier version, then new events logged in the version of iDRAC before it was rolled back may be displayed as an unknown event.
Description New SEL events were introduced in iDRAC versions 4.4x. If iDRAC is rolled back to an earlier version, then new events logged in the version of iDRAC before it was rolled back may be displayed as an unknown event.
Workaround N/A
Systems Affected All PowerEdge Rx5x5 or Cx5x5 series servers supported by this release.
Tracking number 186384
Table 6. PR1 & PR10 Lifecycle logs displayed during Retire and Repurpose operation PR1 & PR10 logs are displayed in Lifecycle logs for PSUs when Retire and Repurpose operation is executed. This doesn't impact server functionality.
Description PR1 & PR10 logs are displayed in Lifecycle logs for PSUs when Retire and Repurpose operation is executed. This doesn't impact server functionality.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 186119
Table 7. After a warm reboot, LC logs display Disk Inserted After performing a server warm reboot, iDRAC may report Disk Inserted in LC logs for drives behind HBA. Please ignore the log entry.
Description After performing a server warm reboot, iDRAC may report Disk Inserted in LC logs for drives behind HBA. Please ignore the log entry.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 144819 and 141414
Table 8. Repetitive PR7 messages related to PSU in LC logs after a system erase operation When the system is powered on manually after performing a system erase on LC data, several messages are displayed in LC logs for PSU stating “PR7 New device detected: POWER SUPPLY (PSU.Slot.X)”.
Description When the system is powered on manually after performing a system erase on LC data, several messages are displayed in LC logs for PSU stating “PR7 New device detected: POWER SUPPLY (PSU.Slot.X)”.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 129440

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\