Description | HBA controller firmware version that was updated through OS is not displayed in iDRAC. |
Workaround | Perform an iDRAC reset or cold boot the system. |
Systems Affected | All systems supported by this release with HBA 330 or HBA 355 controller. |
Tracking number | 236357 |
Description | iDRAC may not display the drive speed for SAS4 drives. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 230060 |
Description | If iDRAC and PERC have the same Key Ids then PERC Rekey command fails. |
Workaround | Use the iDRAC Rekey command instead of PERC Rekey. |
Systems Affected | All systems supported by this release. |
Tracking number | 230629/189445 |
Description | Maximum capable speed for SAS4 drives that are configured with PERC9, PERC10, or PERC 11 is reported as Unknown in iDRAC. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 230290 |
Description | After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message. |
Workaround | Restart the host system. |
Systems Affected | All systems supported by this release. |
Tracking number | 197049 |
Description | When existing VD is deleted from iDRAC GUI using delete VD operation from the Virtual disk option and then added to pending operation, the pending operation displays no information. However, the delete VD pending operation is created successfully. |
Workaround | To successfully delete the VD and add to pending operations, perform the following steps:
|
Systems Affected | All systems supported by this release. |
Tracking number | 184393 |