Description | After BIOS recovery is complete, Auto Power-on not Initiating. |
Workaround | Power on the system manually to complete BIOS recovery process. |
Systems Affected | All 15th generation of PowerEdge servers with AMD. |
Tracking number | 232664/233395 |
Description | Updating iDRAC firmware to version 4.40.00.00 or later may cause the vFlash partitions to detach on first boot after the update. |
Workaround | Reattach the detached vFlash partitions through any iDRAC interfaces after the first boot. |
Systems Affected | All systems supported by this release. |
Tracking number | 194849 |
Description | After updating backplane firmware to a newer version and then updating it back to a previous version from host OS, the backplane information is not displayed while trying to apply the firmware Rollback. |
Workaround | Perform the following:
|
Systems Affected | All systems supported by this release. |
Tracking number | 184368 |
Description | iDRAC time will not synchronize when Server Configuration Profile was exported with SNTP settings and then imported with SNTP settings. |
Workaround | Configure NTP settings and export the Server configuration Profile. Import the Server configuration profile with NTP and manually configure SNTP settings. |
Systems Affected | All systems supported by this release. |
Tracking number | 181069 |
Description | While the system is in power off state, iDRAC fails to obtain the current time after it is reset. Older logs are displayed until iDRAC synchronizes with current time. |
Workaround | N/A |
Systems Affected | All PowerEdge Rxxx5/Cxxx5 systems supported by this release. |
Tracking number | 183347 |
Description | iDRAC may display stale or inaccurate information when there is a communication failure between iDRAC and CMC. |
Workaround | N/A |
Systems Affected | PowerEdge FC640 |
Tracking number | 226633 |