Storage and storage controllers

Table 1. PCIe Slot Details page only listing one NVMe SSD device iDRAC PCIe Slot Details page displays information about only one NVMe SSD device that is installed instead of all four devices.
Description iDRAC PCIe Slot Details page displays information about only one NVMe SSD device that is installed instead of all four devices.
Workaround N/A
Systems Affected PowerEdge XR4520c and PowerEdge XR4510c
Tracking number 229012
Table 2. LC logs display incorrect version change for disks After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message.
Description After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message.
Workaround Restart the host system.
Systems Affected All systems supported by this release.
Tracking number 197049
Table 3. LC logs display incorrect version change for disks After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message.
Description After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message.
Workaround Restart the host system.
Systems Affected All systems supported by this release.
Tracking number 197049
Table 4. Deleting VD creates pending operation with empty data When existing VD is deleted from iDRAC GUI using delete VD operation from the Virtual disk option and then added to pending operation, the pending operation displays no information. However, the delete VD pending operation is created successfully.
Description When existing VD is deleted from iDRAC GUI using delete VD operation from the Virtual disk option and then added to pending operation, the pending operation displays no information. However, the delete VD pending operation is created successfully.
Workaround To successfully delete the VD and add to pending operations, perform the following steps:
  1. Select the Configuration option in iDRAC GUI
  2. Select Storage Configuration, then select the Controller and click Apply now.
Systems Affected All systems supported by this release.
Tracking number 184393