iDRAC9 Version 6.00.15.00 Release Notes

PDF

iDRAC firmware

Table 1. LC logs displaying RAC1198 error After an AC power cycle during an iDRAC firmware update, Lifecycle logs may display RAC1198 message stating "Unable to update the LCD panel firmware either because of connection issues or the LCD bezel is damaged."
Description After an AC power cycle during an iDRAC firmware update, Lifecycle logs may display RAC1198 message stating "Unable to update the LCD panel firmware either because of connection issues or the LCD bezel is damaged."
Workaround No action is required as there is no functional impact.
Systems Affected PowerEdge R7625
Tracking number 240671
Table 2. System not powering on automatically after BIOS recovery After BIOS recovery is complete, Auto Power-on is not Initiating.
Description After BIOS recovery is complete, Auto Power-on not Initiating.
Workaround Power on the system manually to complete BIOS recovery process.
Systems Affected All systems supported by this release.
Tracking number 232664/233395
Table 3. iDRAC time fails to synchronize when Server Configuration Profile is imported with SNTP settingsiDRAC time will not synchronize when Server Configuration Profile was exported with SNTP settings and then imported with SNTP settings.
Description iDRAC time will not synchronize when Server Configuration Profile was exported with SNTP settings and then imported with SNTP settings.
Workaround Configure NTP settings and export the Server configuration Profile. Import the Server configuration profile with NTP and manually configure SNTP settings.
Systems Affected All systems supported by this release.
Tracking number 181069
Table 4. iDRAC unable to obtain the current time after rebootWhile the system is in power off state, iDRAC fails to obtain the current time after it is reset. Older logs are displayed until iDRAC synchronizes with current time.
Description While the system is in power off state, iDRAC fails to obtain the current time after it is reset. Older logs are displayed until iDRAC synchronizes with current time.
Workaround N/A
Systems Affected All PowerEdge Rxxx5/Cxxx5 systems supported by this release.
Tracking number 183347