iDRAC9 Version 5.10.00.00 Release Notes

PDF

Storage and storage controllers

Table 1. Unable to update SED firmware LC logs may report firmware update of a locked SED as successful even though updating firmware for a locked drive is not supported.
Description LC logs may report firmware update of a locked SED as successful even though updating firmware for a locked drive is not supported.
Workaround Ignore the LC logs entry. Before performing a firmware update, ensure that the drive is unlocked.
Systems Affected All systems supported by this release.
Tracking number 208345
Table 2. Cryptographic erase fails on the root port attached drive
Description After unlocking the root port attached drive, cryptographic erase may fail on the drive.
Workaround Perform Racreset to recover the server from the issue state and then try the operation again.
Systems Affected All systems supported by this release.
Tracking number 214972
Table 3. SCP import job fails to secure the drive Secure erase and enable security operation on a secured drive using Server Configure Profile (SCP) import operation fails if Auto Secure option is disabled.
Description Secure erase and enable security operation on a secured drive using Server Configure Profile (SCP) import operation fails if Auto Secure option is disabled.
Workaround Enable Auto Secure option before the import operation or secure the drive using any iDRAC interfaces after import operation.
Systems Affected All systems supported by this release.
Tracking number 213729
Table 4. LC logs display incorrect version change for disks After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message.
Description After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message.
Workaround Restart the host system.
Systems Affected All systems supported by this release.
Tracking number 197049
Table 5. Deleting VD creates pending operation with empty data When existing VD is deleted from iDRAC GUI using delete VD operation from the Virtual disk option and then added to pending operation, the pending operation displays no information. However, the delete VD pending operation is created successfully.
Description When existing VD is deleted from iDRAC GUI using delete VD operation from the Virtual disk option and then added to pending operation, the pending operation displays no information. However, the delete VD pending operation is created successfully.
Workaround To successfully delete the VD and add to pending operations, perform the following steps:
  1. Select the Configuration option in iDRAC GUI
  2. Select Storage Configuration, then select the Controller and click Apply now.
Systems Affected All systems supported by this release.
Tracking number 184393