- Release Summary
Description | During host reboot, UEFI0285 message may be displayed if a TPM is present in the system. |
Workaround | Ignore the message and continue to boot the system. |
Systems Affected | All 15th generation of PowerEdge systems supported by this release. |
Tracking number | 210472 |
Description | If the LC logs display the message ID SWC5011, and LC log for SYS1000 (system powering on) is not generated then system may not power on. |
Workaround | Perform an iDRAC reboot. |
Systems Affected | All 15th generation of PowerEdge systems supported by this release. |
Tracking number | 203464 |
Description | vMedia performance may be degraded when using it in Shared LOM mode with the QLogic QL41000 series OCP3 adapters with firmware version 15.15.11 and later. |
Workaround | Use a different LOM card or downgrade firmware version of QL41000 adapter. |
Systems Affected | All systems supported by this release. |
Tracking number | 199920 |
Description | Displays rendering at higher resolution such as 1152x864, 1280x800, 1280x1024, 1400x900, 1600x900, 1600x1200, 1680x1050, 1920x1080, or 1920x1200 may cause a degradation in video quality. |
Workaround | Change the display resolution to 1024x768 or lower. |
Systems Affected | All systems supported by this release. |
Tracking number | 196892 |
Description | Internal buffer overrun may cause a lag in mouse or keyboard operation in Virtual console when the display resolution is set to 1920x1200. |
Workaround | Switch the display to default (1024x768) or lower resolutions. |
Systems Affected | All systems supported by this release. |
Tracking number | 199758 |
Description | Virtual console display from iDRAC GUI is blurred for a fraction of second and gets corrected automatically when opened in Google chrome. |
Workaround | Use any other browser. |
Systems Affected | All systems supported by this release. |
Tracking number | 182595 |
Description | Some keys or key combination may not provide the correct output for languages other than english. |
Workaround | Use the physical keyboard or Windows On-Screen Keyboard. |
Systems Affected | All systems supported by this release. |
Tracking number | 181505 |
Description | Local video does not turn off and remains on, regardless of the local video server settings in iDRAC virtual console. |
Workaround | N/A |
Systems Affected | PowerEdge C6525, PowerEdge C6400. |
Tracking number | 171650 |
Description | Changing the Remote Presence Port number through virtual console settings page may cause a system restart, further causing a session timeout for iDRAC GUI. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 144597 |