- Release Summary
Description | After performing a PSU firmware update through DUP method, only one sled powers on automatically while others remain powered off. |
Workaround | Use iDRAC GUI to power on the remaining sleds. |
Systems Affected | PowerEdge C6420 |
Tracking number | 209713 |
Description | The property ManagedSystemSize may display an incorrect value in the iDRAC system inventory page. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 212710 |
Description | After an iDRAC firmware update, iDRAC GUI or remote RACADM may fail to display information about the second PSU. |
Workaround | Perform an iDRAC reset. |
Systems Affected | All systems supported by this release. |
Tracking number | 207006 |
Description | System fans may throttle at a higher speed after iDRAC is upgraded to the latest version. |
Workaround | Perform an iDRAC reset or racreset. |
Systems Affected | All systems supported by this release. |
Tracking number | 211724 |
Description | After downgrading iDRAC firmware from version 5.00.00.00 to any previous versions, a Crashcapture with empty file names is displayed in the Troubleshooting page even though the file does not exist. Capturing the crash video again may return an invalid file with extension type appended 1.mpg. |
Workaround | Reset the iDRAC to default configuration. |
Systems Affected | All systems supported by this release. |
Tracking number | 199759 |
Description | Updating iDRAC firmware to version 4.40.00.00 or later may cause the vFlash partitions to detach on first boot after the update. |
Workaround | Reattach the detached vFlash partitions through any iDRAC interfaces after the first boot. |
Systems Affected | All systems supported by this release. |
Tracking number | 194849 |
Description | After updating backplane firmware to a newer version and then updating it back to a previous version from host OS, the backplane information is not displayed while trying to apply the firmware Rollback. |
Workaround | Perform the following:
|
Systems Affected | All systems supported by this release. |
Tracking number | 184368 |
Description | iDRAC time will not synchronize when Server Configuration Profile was exported with SNTP settings and then imported with SNTP settings. |
Workaround | Configure NTP settings and export the Server configuration Profile. Import the Server configuration profile with NTP and manually configure SNTP settings. |
Systems Affected | All systems supported by this release. |
Tracking number | 181069 |
Description | While the system is in power off state, iDRAC fails to obtain the current time after it is reset. Older logs are displayed until iDRAC synchronizes with current time. |
Workaround | N/A |
Systems Affected | All PowerEdge Rxxx5/Cxxx5 systems supported by this release. |
Tracking number | 183347 |