Monitoring and alerting

  1. LC logs not reporting iSM upgrade
    Description
    After iSM is upgraded, LC logs may not report the upgrade with the ISM0007 message.
    Workaround
    N/a
    Systems affected
    All systems supported by this release.
    Tracking number
    202630
  2. LC logs display incorrect message for PSU update
    Description
    While updating PSU firmware with an invalid DUP, LC logs may display "SWC5016 - "Unable to update the firmware of the chassis Power Supply Unit (PSU) because one or more sleds installed on the chassis are currently powered on.".
    Workaround
    N/a
    Systems affected
    All DCS sleds supported by this release.
    Tracking number
    196376
  3. Getting RAC0182 message after upgrading iDRAC firmware
    Description
    LC logs may display the message "RAC0182: The iDRAC firmware was rebooted with the following reason: watchdog" on systems with Intel Ethernet 25G 2P E810-XXV adapter (Firmware v20.0.18), if iDRAC firmware is updated to version 5.xx.
    Workaround
    N/a
    Systems affected
    PowerEdge XE8545
    Tracking number
    200573
  4. SEL events may not be correctly displayed in the earlier versions of iDRAC
    Description
    New SEL events were introduced in iDRAC versions 4.4x. If iDRAC is rolled back to an earlier version, then new events logged in the version of iDRAC before it was rolled back may be displayed as an unknown event.
    Workaround
    N/a
    Systems affected
    All PowerEdge Rx5x5 or Cx5x5 series servers supported by this release.
    Tracking number
    186384
  5. PR1 & PR10 Lifecycle logs displayed during Retire and Repurpose operation
    Description
    PR1 & PR10 logs are displayed in Lifecycle logs for PSUs when Retire and Repurpose operation is executed. This doesn't impact server functionality.
    Workaround
    N/a
    Systems affected
    All systems supported by this release.
    Tracking number
    186119
  6. SupportAssist collection failing
    Description

    Unable to generate SupportAssist collection while iDRAC is under stress and CPU utilization is above 90%.

    Workaround

    Generate SupportAssist collection with only system information option checked.

    Systems affected
    All systems supported by this release.
    Tracking number
    159527
  7. After a warm reboot, LC logs display Disk Inserted
    Description
    After performing a server warm reboot, iDRAC may report Disk Inserted in LC logs for drives behind HBA. Please ignore the log entry.
    Workaround
    N/A
    Systems affected
    All systems supported by this release.
    Tracking number
    144819 and 141414
  8. Repetitive PR7 messages related to PSU in LC logs after a system erase operation
    Description
    When the system is powered on manually after performing a system erase on LC data, several messages are displayed in LC logs for PSU stating “PR7 New device detected: POWER SUPPLY (PSU.Slot.X)”.
    Workaround
    N/A
    Systems affected
    All systems supported by this release.
    Tracking number
    129440

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\