Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

iDRAC9 Version 5.00.00.00 Release Notes

PDF

Automation — API and CLI

  1. Firmware rollback fails with 400 status code
    Description
    Performing firmware rollback using DellUpdateService through Redfish API may fail with a status code 400.
    Workaround
    Use the SimpleUpdate action.
    Systems affected
    All systems supported by this release.
    Tracking number
    201442
  2. RLCE reports Incorrect value for fan sensor
    Description
    Redfish Life Cycle Events may report incorrect data for fan sensor URI after a hot pluggable fan is removed.
    Workaround
    Restart the host system.
    Systems affected
    All systems supported by this release.
    Tracking number
    193777
  3. TelemetryService Redfish URI displaying removed components
    Description
    TelemetryService Redfish URI /redfish/v1/TelemetryService continues to display the FQDD of a removed component under the path Dell OEM FQDDList.
    Workaround
    Check the FQDDs in the hardware inventory.
    Systems affected
    All systems supported by this release.
    Tracking number
    202798
  4. SCP jobs failing through RACADM
    Description
    Updating configuration for NVMe Over FC fails with an LC log error stating " Unable to configure the target settings properties of the Fibre Channel in Mezzanine 1C Port 1".
    Workaround
    Change configuration through iDRAC HII with IOIDOpt Disabled.
    Systems affected
    All systems that support Qlogic FC adapter with NVMe Over FC features.
    Tracking number
    199872
  5. RACADM autocomplete action not working on FirstNVMeTarget and SecondNVMeTgt
    Description
    In RACADM cd mode, autocomplete action for FirstNVMeTarget returns incorrect suggestion list and for SecondNVMeTgt or SeventhNVMeTgt it does not return the expected output or stops the process.
    Workaround
    Perform the following:
    • If autocomplete action is not responding, press Enter to recover the RACADM prompt
    • Use autocomplete action without entering RACADM cd mode.
    Systems affected
    All systems supported by this release.
    Tracking number
    194894
  6. Service Validator reporting errors for Redfish API services
    Description
    To continue support firmware backward compatible, you may get errors for Redfish API services in the Service Validator. They do not have any functional impact on the system and may be ignored.
    Workaround
    N/a
    Systems affected
    All systems supported by this release.
    Tracking number
    183321
  7. Performing GET with Top query parameter returns no error
    Description
    Top query on a Parity URI instance returns complete response instead of an error code.
    Workaround
    N/a
    Systems affected
    All systems supported by this release.
    Tracking number
    175801
  8. Performing GET method on chassis PCIe slots displays all PCIe slots
    Description
    iDRAC displays all the empty and populated slots as part of PCIe empty slot feature. All the 8 slots entries are seen under one sled even though only few are associated with that particular sled.
    Workaround
    N/a
    Systems affected
    PowerEdge FC640, PowerEdge R740XD
    Tracking number
    172943
  9. Uploaded firmware link not available in SoftwareImages property
    Description

    While performing GET method on BIOS or Manager Schema through Redfish, the SoftwareImages property may not display the uploaded firmware link.

    Workaround

    N/A

    Systems affected
    All systems supported by this release.
    Tracking number
    156737
  10. Attributes for CNA cards not displayed through Redfish or RACADM interface
    Description
    If the partitions are disabled on FCoE capable CNA cards, few HII attributes values for WWN, VirtWWN, WWPN, VirtWWPN are displayed in the iDRAC GUI's Network page. However, the same data is not displayed when Get commands are performed in Redfish and RACADM interfaces.
    Workaround
    N/A
    Systems affected
    All systems supported by this release.
    Tracking number
    151560
  11. Unable to create a recurring job after same job was completed
    Description
    Creating a recurring job will fail if the same job was completed recently and its Task ID still exists.
    Workaround
    Wait for ten minutes for the Task ID to be deleted.
    Systems affected
    All systems supported by this release.
    Tracking number
    147501
  12. Get operation not displaying model or serial number for PCIe devices
    Description
    If you perform a Get operation for a PCIe device using Redfish API, the response may not display the model and serial number of the device.
    Workaround
    N/A
    Systems affected
    All systems supported by this release.
    Tracking number
    111564

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\