- Release Summary
Description | Maximum capable speed for SAS4 drives that are configured with PERC9, PERC10, or PERC 11 is reported as Unknown in iDRAC. |
Workaround | N/A |
Systems Affected | All systems supported by this release. |
Tracking number | 230290 |
Description | Secure erase and enable security operation on a secured drive using Server Configure Profile (SCP) import operation fails if Auto Secure option is disabled. |
Workaround | Enable Auto Secure option before the import operation or secure the drive using any iDRAC interfaces after import operation. |
Systems Affected | All systems supported by this release. |
Tracking number | 213729 |
Description | After a disk firmware upgrade, LC logs may report it as a firmware downgrade with PR36 message. |
Workaround | Restart the host system. |
Systems Affected | All systems supported by this release. |
Tracking number | 197049 |
Description | When existing VD is deleted from iDRAC GUI using delete VD operation from the Virtual disk option and then added to pending operation, the pending operation displays no information. However, the delete VD pending operation is created successfully. |
Workaround | To successfully delete the VD and add to pending operations, perform the following steps:
|
Systems Affected | All systems supported by this release. |
Tracking number | 184393 |