Automation — API and CLI

Table 1. RLCE reports Incorrect value for fan sensor Redfish Life Cycle Events may report incorrect data for fan sensor URI after a hot pluggable fan is removed.
Description Redfish Life Cycle Events may report incorrect data for fan sensor URI after a hot pluggable fan is removed.
Workaround Restart the host system.
Systems Affected All systems supported by this release.
Tracking number 193777
Table 2. TelemetryService Redfish URI displaying removed components TelemetryService Redfish URI /redfish/v1/TelemetryService continues to display the FQDD of a removed component under the path Dell OEM FQDDList.
Description TelemetryService Redfish URI /redfish/v1/TelemetryService continues to display the FQDD of a removed component under the path Dell OEM FQDDList.
Workaround Check the FQDDs in the hardware inventory.
Systems Affected All systems supported by this release.
Tracking number 202798
Table 3. SCP jobs failing through RACADM Updating configuration for NVMe Over FC fails with an LC log error stating " Unable to configure the target settings properties of the Fibre Channel in Mezzanine 1C Port 1".
Description Updating configuration for NVMe Over FC fails with an LC log error stating " Unable to configure the target settings properties of the Fibre Channel in Mezzanine 1C Port 1".
Workaround Change configuration through iDRAC HII with IOIDOpt Disabled.
Systems Affected All systems that support Qlogic FC adapter with NVMe Over FC features.
Tracking number 199872
Table 4. RACADM autocomplete action not working on FirstNVMeTarget and SecondNVMeTgt In RACADM cd mode, autocomplete action for FirstNVMeTarget returns incorrect suggestion list and for SecondNVMeTgt or SeventhNVMeTgt it does not return the expected output or stops the process.
Description In RACADM cd mode, autocomplete action for FirstNVMeTarget returns incorrect suggestion list and for SecondNVMeTgt or SeventhNVMeTgt it does not return the expected output or stops the process.
Workaround Perform the following:
  • If autocomplete action is not responding, press Enter to recover the RACADM prompt
  • Use autocomplete action without entering RACADM cd mode.
Systems Affected All systems supported by this release.
Tracking number 194894
Table 5. Service Validator reporting errors for Redfish API services To continue support firmware backward compatible, you may get errors for Redfish API services in the Service Validator. They do not have any functional impact on the system and may be ignored.
Description To continue support firmware backward compatible, you may get errors for Redfish API services in the Service Validator. They do not have any functional impact on the system and may be ignored.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 183321
Table 6. Performing GET with Top query parameter returns no error Top query on a Parity URI instance returns complete response instead of an error code.
Description Top query on a Parity URI instance returns complete response instead of an error code.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 175801
Table 7. Performing GET method on chassis PCIe slots displays all PCIe slots iDRAC displays all the empty and populated slots as part of PCIe empty slot feature. All the 8 slots entries are seen under one sled even though only few are associated with that particular sled.
Description iDRAC displays all the empty and populated slots as part of PCIe empty slot feature. All the 8 slots entries are seen under one sled even though only few are associated with that particular sled.
Workaround N/A
Systems Affected PowerEdge FC640, PowerEdge R740XD
Tracking number 172943
Table 8. Uploaded firmware link not available in SoftwareImages property While performing GET method on BIOS or Manager Schema through Redfish, the SoftwareImages property may not display the uploaded firmware link.
Description While performing GET method on BIOS or Manager Schema through Redfish, the SoftwareImages property may not display the uploaded firmware link.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 156737
Table 9. Attributes for CNA cards not displayed through Redfish or RACADM interface If the partitions are disabled on FCoE capable CNA cards, few HII attributes values for WWN, VirtWWN, WWPN, VirtWWPN are displayed in the iDRAC GUI's Network page. However, the same data is not displayed when Get commands are performed in Redfish and RACADM interfaces.
Description If the partitions are disabled on FCoE capable CNA cards, few HII attributes values for WWN, VirtWWN, WWPN, VirtWWPN are displayed in the iDRAC GUI's Network page. However, the same data is not displayed when Get commands are performed in Redfish and RACADM interfaces.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 151560
Table 10. Unable to create a recurring job after same job was completed Creating a recurring job will fail if the same job was completed recently and its Task ID still exists.
Description Creating a recurring job will fail if the same job was completed recently and its Task ID still exists.
Workaround Wait for ten minutes for the Task ID to be deleted.
Systems Affected All systems supported by this release.
Tracking number 147501
Table 11. Get operation not displaying model or serial number for PCIe devices If you perform a Get operation for a PCIe device using Redfish API, the response may not display the model and serial number of the device.
Description If you perform a Get operation for a PCIe device using Redfish API, the response may not display the model and serial number of the device.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 111564