Monitoring and alerting

Table 1. LC logs not reporting iSM upgradeAfter iSM is upgraded, LC logs may not report the upgrade with the ISM0007 message.
Description After iSM is upgraded, LC logs may not report the upgrade with the ISM0007 message.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 202630
Table 2. LC logs display incorrect message for PSU update While updating PSU firmware with an invalid DUP, LC logs may display "SWC5016 - "Unable to update the firmware of the chassis Power Supply Unit (PSU) because one or more sleds installed on the chassis are currently powered on."
Description While updating PSU firmware with an invalid DUP, LC logs may display "SWC5016 - "Unable to update the firmware of the chassis Power Supply Unit (PSU) because one or more sleds installed on the chassis are currently powered on."
Workaround N/A
Systems Affected All DCS sleds supported by this release.
Tracking number 196376
Table 3. Getting RAC0182 message after upgrading iDRAC firmware LC logs may display the message "RAC0182: The iDRAC firmware was rebooted with the following reason: watchdog" on systems with Intel Ethernet 25G 2P E810-XXV adapter (Firmware v20.0.18), if iDRAC firmware is updated to version 5.xx.
Description LC logs may display the message "RAC0182: The iDRAC firmware was rebooted with the following reason: watchdog" on systems with Intel Ethernet 25G 2P E810-XXV adapter (Firmware v20.0.18), if iDRAC firmware is updated to version 5.xx.
Workaround N/A
Systems Affected PowerEdge XE8545
Tracking number 200573
Table 4. SEL events may not be correctly displayed in the earlier versions of iDRAC New SEL events were introduced in iDRAC versions 4.4x. If iDRAC is rolled back to an earlier version, then new events logged in the version of iDRAC before it was rolled back may be displayed as an unknown event.
Description New SEL events were introduced in iDRAC versions 4.4x. If iDRAC is rolled back to an earlier version, then new events logged in the version of iDRAC before it was rolled back may be displayed as an unknown event.
Workaround N/A
Systems Affected All PowerEdge Rx5x5 or Cx5x5 series servers supported by this release.
Tracking number 186384
Table 5. PR1 & PR10 Lifecycle logs displayed during Retire and Repurpose operation PR1 & PR10 logs are displayed in Lifecycle logs for PSUs when Retire and Repurpose operation is executed. This doesn't impact server functionality.
Description PR1 & PR10 logs are displayed in Lifecycle logs for PSUs when Retire and Repurpose operation is executed. This doesn't impact server functionality.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 186119
Table 6. SupportAssist collection failing Unable to generate SupportAssist collection while iDRAC is under stress and CPU utilization is above 90%.
Description Unable to generate SupportAssist collection while iDRAC is under stress and CPU utilization is above 90%.
Workaround Generate SupportAssist collection with only system information option checked.
Systems Affected All systems supported by this release.
Tracking number 159527
Table 7. After a warm reboot, LC logs display Disk Inserted After performing a server warm reboot, iDRAC may report Disk Inserted in LC logs for drives behind HBA. Please ignore the log entry.
Description After performing a server warm reboot, iDRAC may report Disk Inserted in LC logs for drives behind HBA. Please ignore the log entry.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 144819 and 141414
Table 8. Repetitive PR7 messages related to PSU in LC logs after a system erase operation When the system is powered on manually after performing a system erase on LC data, several messages are displayed in LC logs for PSU stating “PR7 New device detected: POWER SUPPLY (PSU.Slot.X)”.
Description When the system is powered on manually after performing a system erase on LC data, several messages are displayed in LC logs for PSU stating “PR7 New device detected: POWER SUPPLY (PSU.Slot.X)”.
Workaround N/A
Systems Affected All systems supported by this release.
Tracking number 129440

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\